JUNOS Internet Software Network Operations Guide: Hardware
!
82
Using the Basic Monitoring Method
Chassis
Component
Alarm Condition
SIB
A spare SIB is missing.
An SIB failed.
A spare SIB failed.
A SIB has an out-of-range or
invalid temperature reading.
An SIB is missing.
An SIB failed.
SPMB
A local SPMB is offline.
Temperature
The chassis temperature
exceeded 55 degrees, the fans
turned on to full speed, and
one or more fans have failed.
The chassis temperature
exceeded 65 degrees C and
the fans have been turned on
to full speed.
The chassis temperature
exceeded 65 degrees C and a
fan failed. If this condition
persists for more than 4
minutes, the router shuts
down.
Chassis temperature exceeded
75 degrees C. If this condition
persists for more than 4
minutes, the router shuts
down.
The temperature sensor failed. For technical support,
Alarm
Remedy
Severity
Insert a spare SIB into
Yellow
an empty slot.
Replace the failed SIB.
Yellow
Replace the failed SIB.
Yellow
Replace the failed SIB.
Yellow
Insert an SIB into empty
Red
slot.
Replace the failed SIB.
Red
Reset the Control Board.
Red
If this fails, replace the
Control Board.
!
Check the room
Yellow
temperature.
!
Check the air filter
and replace it.
!
Check the air flow.
!
Check the fan.
!
Check the room
Yellow
temperature.
!
Check the air filter
and replace it.
!
Check the air flow.
!
Check the fan.
!
Check the room
Red
temperature.
!
Check the air filter
and replace it.
!
Check the air flow.
!
Check the fan.
!
Check the room
Red
temperature.
!
Check the air filter
and replace it.
!
Check the air flow.
!
Check the fan.
Red
open a support case
using the Case Manager
link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within
the United States) or
1-408-745-9500 (outside
the United States).