Check The Alarm Indicators On The Craft Interface; Display Current Cooling System Alarms - Juniper JUNOS - NETWORK OPERATION GUIDE REV1 Network Operation Manual

Internet software for m-series and t-series routing platforms
Table of Contents

Advertisement

JUNOS Internet Software Network Operations Guide: Hardware
Step 1: Check the Alarm Indicators on the Craft Interface
Action
Sample Output
What It Means
Alternative Action
Step 2: Display Current Cooling System Alarms
Action
Sample Output
What It Means
!
270
Checking the Cooling System Alarms
To check the craft interface alarm indicators, use the following CLI command:
user@host> show chassis craft-interface
user@host> show chassis craft-interface
Status
Measurement
Red alarm:
LED on, relay on
Yellow alarm:
LED off, relay off
Host OK LED:
On
Host fail LED: Off
[...Output truncated...]
LCD screen:
+--------------------+
|myrouter
|2 Alarms active
|R: Fan Failure
|R: Fan Removed
+--------------------+
The command output displays the alarm indicator status. The alarm indicators can
be either On or Off . If an indicator is on, an alarm has occurred. The command
output also displays the active alarms on the craft interface LCD display. To list the
current alarms, use the show chassis alarms command.
You can also physically view the craft interface to see the alarm indicators and
alarm descriptions displayed on the LCD display.
For information that triggers cooling system alarms in each router type, see "Gather
Component Alarm Information" on page 60. For fan alarms by router type, see
Table 69 on page 271.
To display the current cooling system alarms, use the following CLI command:
user@host> show chassis alarms
user@host> show chassis alarms
2 alarms currently active
Alarm time
2002-04-08 15:25:12 PDT
2002-04-08 15:25:12 PDT
The command output displays the current cooling system alarms, including the
time and date stamp, severity level, and description. Table 69 on page 271 shows
the possible cooling system alarms for each router type. The alarm LCD short
version appears on the craft interface LCD display. The alarm long version appears
at the CLI when you use the show chassis alarms command.
|
|
|
|
Class
Description
Major
Rear left fan stopped spinning
Major
Rear left fan Failure