Temperature Compensation - CARLO GAVAZZI UDM 35 - PROGRAMMING Programming Manual

Digital panel meter
Hide thumbs Also See for UDM 35 - PROGRAMMING:
Table of Contents

Advertisement

UDM 35/40 PANEL METER USER MANUAL
LSX and HSX input modules offer True RMS (trnS) or DC measurement
(dC). Use
Press
keys to select Input signal integration time value (intt).
If all zeros "0000" is selected, "Auto" will be displayed and the value will be
automatically calculated from 100ms – 999.9 ms. Press
Press
to advance to next program step sequence.
Cold Junction Compensation (CJC) Temperature Compensation
Available only when TRX input module is installed.
TRX module with Thermocouple (tC) requires configuration of Cold
Junction Compensation (CJC). Press
to enter.
keys to make selection. Press
.
to confirm.
key to advance to CJC Then
6