Chapter 10
Field
Control
The first column shows the current state.
Three buttons are available to initiate an action to either, power
Power status
on, power off or restart the server. Dependant on the current sta-
tus Power on or Power off is disabled.
Reboot the Rackable Server by sending a 500ms reset signal to
Reboot
the server.
Spawn the Java Telnet applet or the local Telnet/SSH application
Connect
to connect directly to the port.
LED Mgmt
To control the LED in the front of the Rackable Server.
LED
The first columns shows the current status of the LED. Three but-
Management
tons are available to select the activity of the status LED: turn on,
turn off and blinking. Either of these buttons is disabled.
LCD Mgmt
Currently
Shows the message that is currently displayed on the LCD dis-
displayed
play.
message
This function clears the LCD display.
Erase
The saved message stays saved to flash.
Save
Save currently displayed message to flash memory.
The first columns shows the current status: Yes or No.
Show saved
This parameter defines which message is displayed upon startup
LCD message
of the server, either the saved message or the standard: "Rack-
upon startup
able Systems Phantom Vx.xx".
Set a contrast for the LCD panel.
Contrast
The default is 50, the range is 0 – 100.
Phantom
Properties
Temperature
Indicates current temperature inside the Rackable Systems Server.
Time in seconds before the server starts up after applying power
Power delay
(0-98 seconds, 99 means no power on delay).
The power sense option toggles between sensing server power
on the reset header or on the J7 connector. Most applications will
Power sense
use the "Reset" option. This option should be set before shipping
from Rackable Systems, but may need to be reset if somehow
changed after shipping.
Configure the baud rate used to communicate with the Rackable
Communication
Systems Management Card. For this change to become effective
settings
reset or power-cycle the Management card, and be sure to
Baud Rate
switch the port settings in the Digi CM port settings.
Rackable Systems Management Card