System Send_Commands (Cont.)
PBIL
Assigns the push-
button illumina-
tion modes.
PKEYP
Displays aster-
isks (*) for keypad
entries.
PPOF
Closes a specific
popup page.
PPON
Opens a specific
popup page.
QBEEP
Stops all beeps.
4" Color Touch Panels with Audio
The button illumination features are also set using the three illumination buttons on the
Adjust Sensors page.
Syntax:
"'PBIL,<n>'"
Variable:
n = Pushbutton illumination mode value:
Mode # <n>
Mode Description
0
Disabled (illumination Off)
1
Enabled (illumination On)
2
PIR Automatic (illumination based on PIR detection)
3
LS Automatic - button illumination is based on the
light sensor detection of a dim or normal room mode.
PIR/LS Automatic - a combination of options 2 and 3.
4
The order of precedence is PIR then the LS.
Example:
SEND_COMMAND TP,"'PBIL,2'"
Sets the pushbuttons to illuminate when the Passive Infrared sensor (PIR) detects the
presence of a user.
Syntax:
"'PKEYP-<number string>'"
Variable:
number string = 0 - 9999
Example:
SEND_COMMAND TP,"'PKEYP-1988'"
Displays the touch panel keypad with **** instead of 1988.
Syntax:
"'PPOF-<page name>'"
Variable:
page name = 1 - 50 ASCII characters
Example:
SEND_COMMAND TP,"'PPOF-Popup Page 1'"
Closes Popup Page 1.
Syntax:
"'PPON-<page name>'"
Variable:
page name = 1 - 50 ASCII characters
Example:
SEND_COMMAND TP,"'PPON-Popup Page 1'"
Opens Popup Page 1.
Syntax:
"'QBEEP'"
Example:
SEND_COMMAND TP,"'QBEEP'"
Stops all beeps, including "'ABEEP'", "'ADBEEP'", and AXlink beeps.