7. The "Choose Type" menu offers different host drive types. For this example, we select
"RAID 5 + Hot Fix" and press <Enter>.
8. For security reasons, you will be asked if you want to use the selected disk to create a host
drive. StorCon displays a warning that all data will be destroyed after confirmation. Confirm
the choice by pressing <Y>. StorCon creates a new host drive.
9. Enter the appropriate drive capacity and press <Enter>.
10. The new host drive is created. Press <F10> to refresh and begin the build process. Its status is
still "build," since the Intel RAID Controller SRCU31 synchronizes both drives.
✏
NOTE
The array build will continue as a background task. Exit StorCon, by pressing <ESC>, and the
array build will continue in the background after BIOS POST upon reboot. You can then proceed
with OS installation while the array continues the build process in the background.
11. When leaving StorCon, by pressing <ESC>, a progress window displays the estimated
completion time for the build process.
12. Upon successful completion of the build process, the disk array changes to Ready status.
40
Intel RAID SRCU31 Users Guide
Need help?
Do you have a question about the SRCU31A - Server RAID U3-1A Controller and is the answer not in the manual?