Network Settings (Net) Page; Display Setup (Disp) Page; Link Mode; Mac Adr - Yamaha DME64N - Pro Audio Owner's Manual

Digital mixing engine
Hide thumbs Also See for DME64N - Pro Audio:
Table of Contents

Advertisement

Network Settings (Net) Page

Shows the Ethernet network address and other parameters.
1
2
3
4
5
1 Master/Slave
Indicates whether or not the device is functioning as the
device group master: "Master" or "Slave."
Master: the device is the device group master.
Slave: the device is a device group slave.
Edit using the "List Parameters" editing procedure
described on page 38.
NOT E
Device group status of ICP1 is fixed to "Slave." This cannot be
changed.
NOT E
Make sure that one device group master is assigned for each
device group.
If no device group master is assigned, no scene information will
appear on the display and scene-related control will not be
possible. Mute operations will also not be possible.

2 IP Adr.

This is the device's IP address.
Edit using the "Numeric Parameters" editing procedure
described on page 36.
Network Address
NOT E
The network addresses of devices in the same device group must
be the same.
NOT E
Device group master's IP address can be changed via the DME
Designer application running on a computer connected to the
unit.
Host Address
3 Master ID
Displays and sets the device group master host address.
N OTE
This is not displayed on the device group master device.

4 Link Mode

Shows the status of the [NETWORK] connector. The
[NETWORK] connector can be set to operate in "10Base-
T" or "100Base-TX" mode.
10Base-T: The [NETWORK] connector is compatible
with 10Base-T operation.
100Base-TX: The 100Base-Tx: [NETWORK] terminal
operates as 100Base-TX if possible. If the network
environment does not support 100Base-TX, it operates as
10Base-T.
Edit using the "List Parameters" editing procedure
described on page 38.

5 MAC Adr.

This is the device's MAC (Media Access Control) address.
N OTE
The MAC address is also known as the Ethernet address, and is
an independent address assigned to all Ethernet devices. No two
devices anywhere in the world can have the same address.

Display Setup (Disp) Page

Provides access to a number of display parameters.
N OTE
The meter fall time (3) is not shown on the ICP1 control panel
display.
1
2
3

1 LCD Contrast

The current LCD contrast setting. This parameter can be
adjusted from 0% through 100%.
Edit using the "Numeric Parameters" editing procedure
described on page 36.
DME64N/DME24N Owner's Manual