Yamaha DME64N - Pro Audio Owner's Manual page 70

Digital mixing engine
Hide thumbs Also See for DME64N - Pro Audio:
Table of Contents

Advertisement

MIDI Data Format
4.1 Program Change (Cnh)
Receive
When the "Program Change Rx Switch" is on, Program Change messages are received on the MIDI channel specified by
the "MIDI Rx Channel" parameter.
If the "Program Change Omni Switch" is also on, however, Program Change messages will be received on all MIDI
channels regardless of the "MIDI Rx Channel" setting.
When a Program Change message is received, the scene assigned to the received program number in the "MIDI Program
Change table" is recalled.
The accepted Bank Select, Program Change range is as follows:
Transmit
When the "Program Change Tx Switch" is on, the corresponding Program Change number will be transmitted as specified
by the "MIDI Program Change table" and "MIDI Tx Channel" settings.
If multiple Program Change numbers are assigned to a single scene, the Bank Select MSB/LSB and Program Change
number corresponding to the lowest number will be transmitted.
Bank Select MSB
Status
Data
Data
Bank Select LSB
Status
Data
Program Change No.
Status
Data
4.2 Active Sensing (FEh)
Receive
MIDI communication will be initialized if no data is received within 300 ms after reception (Running Status, etc., will be
cleared).
Active Sensing
Status
4.3 Control Change (Bnh)
Receive
When the "Control Change Rx Switch" is on, Control Change messages are received on the MIDI channel specified by the
"MIDI Rx Channel" parameter.
If the "Control Change Omni Switch" is also on, however, Control Change messages will be received on all MIDI channels
regardless of the "MIDI Rx Channel" setting.
Control Change parameter resolution is 128 regardless of the parameters effective range. For finer settings use Parameter
Change.
Transmit
When the "Control Change Tx Switch" is on, appropriate Control Change data will be transmitted when a parameter is
edited via the panel controls, as specified by the "MIDI Control Change table" and "MIDI Tx Channel" settings.
Transmission does not occur when switching Configurations.
Refer to "Supplementary Information 1" for cases in which multiple messages are assigned to single parameter.
Status
Data
4.4 Parameter Change (F0h ~ F7h)
Receive
When the "Parameter Change Rx Switch" is On, Parameter Change messages are received on the MIDI channel specified
by the "Device ID (Rx Ch)" parameter.
70
DME64N/DME24N Owner's Manual
Bank Select MSB: 0
Bank Select LSB: 0 ~ 7
Program Change No.: 0 ~ 127
Bnh (1101nnnnb)
00h (00000000b)
nnh (0nnnnnnnb)
Bnh (1101nnnnb)
20h (00100000b)
nnh (0nnnnnnnb)
Cnh (1100nnnnb)
nnh (0nnnnnnnb)
FEh (11111110b)
Bnh (1011nnnnb)
cch (0cccccccb)
vvh (0vvvvvvvb)
Control Change
Control Change No. 0 (Bank Select MSB)
Control Value (Bank Select MSB No.)
Control Change
Control Change No. 32 (Bank Select LSB)
Control Value (Bank Select LSB No.)
Program Change
Program Change No. (0-127)
Active Sensing
Control Change
Control Change No. (1-31,33-95,102-119)
Control Value (0-127)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme24n

Table of Contents