Gas Supply Connection - Dacor ER36D Installation Instructions Manual

Installation instructions
Hide thumbs Also See for ER36D:
Table of Contents

Advertisement

Bare wire
connections
Loop and
spade terminal
connections
L1 terminal
Neutral terminal
L2 terminal
Jumper link
L1 wire
White wire
L2 wire
Strain relief
3 Wire Appliance Cord
Connection -
Where Local Code Permits
L1
L2
10-50P Plug
Installation Instructions
Neutral
Gas Connection
Make sure the gas supply valve is off and that the power to
the range is turned off at the circuit breaker or fuse box prior
to connecting the gas line.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber's putty on gas flex line
connections.
For LP installations, the LP gas tank must have its own
high pressure regulator. This is in addition to the pressure
regulator provided with the range.
The maximum gas supply pressure to the regulator must
never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa.
The range and shut-off valve must be disconnected from the
gas supply piping during any pressure testing exceeding 1/2
p.s.i. (3.5 kPa).
The range must be isolated from the gas supply piping by
closing the shut-off valve during any pressure testing at or
below 1/2 p.s.i. (3.5 kPa).
Check all gas lines for leaks as instructed to avoid a fire or
explosion hazard. Do not use a flame to check for leaks.
NOTE: The gas pressure regulator is pre-set at the factory for
the type of gas intended for use with the appliance. To verify that
the appliance is compatible with the type of gas available, check
the range rating label (see page 3 for location). Ranges intended
for use with LP gas will have "LP" as a part of the model number.
Consult your dealer if the range is not compatible with the type of
gas supplied.
Before sliding the range into the cabinet:
1.
Make sure the gas supply valve is in the off position and that
power to the range is off.
2.
Connect a flexible gas supply line to the gas shut-off valve
previously installed on the stub out. The gas line needs to be
long enough to allow the range to be pulled out for service.
3.
Remove the gas regulator access cover.
4.
Slide the end of the gas line under the back cover into the
regulator compartment from the bottom.
5.
Connect the gas line to the regulator.
6.
Turn all cooktop control valves to the "OFF" position. Turn on
the gas supply.
7.
Check all lines and
connections for leaks
using a soap and
water solution.
8.
After verifying that
there are no gas
leaks, turn off the
gas supply valve
connected to the
range to the "OFF"
position.
9.
Replace the regulator
access cover.
WARNING
Regulator
connection
Gas line
Back of range
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epicure er48dEpicure er36d-cEpicure er48d-c

Table of Contents