960L
MIDI SYSEX
The only Sysex message supported by the 960L is the
"Inquiry Message". The 960L will respond with the standard
d e s c r i p t o r, as defined in
Specification", published by The MIDI Manufacture r s
Association (MMA)
Incoming Inquiry:
MIDI Byte
Description
F0
Sysex header
7E
Non-real-time header
XX
Device ID. The 960L will always respond to its own ID (0) or to 7F.
06
General Information
01
Device Inquiry
F7
EOX
960L's response:
MIDI Byte
Description
F0
Sysex header
7E
Non-realtime header
XX
Device ID. Always 0 in 960L Software V1.0
06
General Information
02
Device ID message
06
Lexicon ID
0C
960L Sysex ID (Device Family Code LSB)
00
Reserved (Device Family Code MSB)
00
Reserved (Device Family Member Code LSB)
00
Reserved (Device Family Member Code MSB)
XX
Major Software Revision
XX
Minor Software Revision
XX
Revision type. 'A' Alpha, 'B' Beta, 'R' Release
00
Unused Revision information
F7
EOX
the