3Com SECPATH U200-CS Installation Manual page 81

Secpath u200 series unified threat management products
Table of Contents

Advertisement

Figure 6-9 Set up a TFTP upgrade environment
The U200-S serves as the TFTP client, and PC serves as the TFTP server.
Connect Ethernet interface GigabitEthernet 0/0 on the U200-S to the PC using a crossover
Ethernet cable. Ensure the connectivity between the U200-S and the PC. In this example, the IP
address of GigabitEthernet 0/0 on the client is 192.168.80.10 and that of the PC is 192.168.80.200.
Enable TFTP Server on PC and set the path where the application file is stored.
The U200 series are not available with TFTP Server software. You need to purchase and install
one yourself.
You can upgrade the applications of the U200 series through GigabitEthernet 0/0 only.
Step2 Configure Ethernet interface parameters on the BootWare menu.
Enter the BootWare main menu and select 3 to enter the Ethernet submenu, where you can select 5 to
enter the Ethernet Parameter Set menu to set the Ethernet parameters.
==================<ETHERNET PARAMETER SET>===================
| Note:
'.' = Clear field.
|
'-' = Go to previous field.
|
Ctrl+D = Quit.
=============================================================
Protocol (FTP or TFTP):tftp
Load File Name
Target File Name
Server IP Address
Local IP Address
:main.bin
:utm.bin
:main.bin
:utm.bin
:192.168.80.200
:192.168.80.10
6-16
|
|
|