II. Fault 2
1)
Symptom
Boot the firewall, upgrade Comware software using TFTP, and the system displays the
following:
Net Port Download Menu:
1:
2:
3:
Enter your choice(1-3): 2
Starting the TFTP download...
Failed to find the updated file
Please check the
2)
Solution
The above symptom is caused by either of the two problems:
The downloaded files are not available.
The paths of the files are not correct.
Confirm that the files to be downloaded are under the path specified by the TFTP
server.
III. Fault 3
1)
Symptom
Boot the firewall, upgrade Comware software using TFTP, and the system displays the
following:
Net Port Download Menu:
1:
2:
3:
Enter your choice(1-3): 2
Starting the TFTP download...
The downloaded software is not a valid version.
Please download the correct version.
2)
Solution
The above problem is caused by the wrong version of the download program, so the
program cannot pass the version authentication. Confirm that the program version is
correct.
Change Net Parameter
Download From Net
Exit to Main Menu
network setting!!
Change Net Parameter
Download From Net
Exit to Main Menu
6-3
Chapter 6 Troubleshooting