When the problem is resolved, the operator powers up and reboots the
system.
The dial-out alert feature is enabled as part of the dial-in setup. See
Section 3.9.
The elements of the dial string and alert string are shown in Table 3–3. Paging
services vary, so you need to become familiar with the options provided by the
paging service you will be using. The RMC supports only numeric messages.
Sets the string to be used by the RMC to dial out when an alert condition occurs.
The dial string must include the appropriate modem commands to dial the
number. In this example, 1-508-555-3333 is the pager number.
Sets the alert string, typically the phone number of the modem connected to the
remote system. The alert string is appended after the dial string, and the
combined string is sent to the modem when an alert condition is detected. In this
example, the system's modem number is 1-508-555-4444.
Enables the RMC to page a remote system operator.
Because the modem is not connected at the COM1 port at this time, the RMC
notifies you that the alert will be enabled at connection.
Clears any alert that may be pending. This ensures that the send alert
command will generate an alert condition.
Forces an alert condition. This command is used to test the setup of the dial-out
alert function. It must be issued from the local serial terminal.
The RMC tries to send the alert immediately. Because the modem is not
connected at the COM1 port at this time, the RMC resets the paging interval to at
most 30 minutes, and will send the alert again. If the pager does not receive the
alert within 30 minutes, re-check your setup.
Clears the current alert so that the RMC can capture a new alert. The last alert
is stored until a new event overwrites it. The Alert Pending field of the status
command becomes NO after the alert is cleared.
Verifies the settings. Check that the Alert Enable field is set to Enabled.
NOTE: If you do not want dial-out paging enabled at this time, enter the disable
alert command after you have tested the dial-out alert function. Alerts
continue to be logged, but no paging occurs.