TABLE
4-5
Trouble
Isolation
Procedure
Maintenance—Type 82
Possible Causes
Area at Fault
17, Low gain in channel A, deflection
about three, Gain switch set to X1***.
Check for shorted D572.
Switching
Multivibrator
@Q565-
Check for trouble in the Switch-
ing
Multivibrator
@Q565-Q575
stage.
19. Low gain, one channel.
Deflec-
tion factor decreased by a factor of
Check for trouble in the Input
Amplifier
of
the
channel
at
20. Low gain in one channel for all
SN 101-2999
fault.
SN 3000-Up
Check for trouble in the Input
Amplifier
of the
channel
at
21. Low gain in one channel for only
one
position
of
the
V/CM_
switch.
GAIN switch set to X1.***
22. No de coupling of the signal.
23. Trace
shifts
position
vertically
when the INPUT connector center con-
ductor is grounded.
les in the Input Cathode Fol-
lower stage V133 or V233, de-+
24. Low gain in
one channel
when
Check the transistors in the channel at fault.
Amplifier
of the channel
at
25. No waveform display using either
channel but trace can be obtained.
Shorted capacitor: C539, C549, or C554.
Check for open R554.
Check
for
no
+12.6-volt
supply
voltage.
26. No waveform display when using
one of the channels. GAIN switch set
Open circuit
between
INPUT connector and
fault; between INPUT connector and R217 and
R226 if Channel B is at fault.
SN
101-2999
For Channel A: check for shorted C117 or C127.
For Channel B: check for shorted C217 or C227.
depending on channel at fault.
27. No waveform display when using
one of the channels. GAIN switch sef
to X10.
Coax cable shorted to ground at either the in-
put or output of the X10 Amplifier at fault.
Amplifier of the channel
at
fault.
Refer to Part 1B.
4-13
Need help?
Do you have a question about the Type 82 PLUG-IN and is the answer not in the manual?
Questions and answers