13 - ERROR MESSAGES
The error is shown on the unit display. In the table below, the "ERROR SHOWED ON SCREEN" column
lists the possible errors, accompanied by a possible cause ("POSSIBLE" CAUSES "column) and a code
error.
ERROR SHOWED ON
SCREEN
[DMX ACTIVE]
[TEMPERATURE ERROR]
[BATTERY ERROR]
[LOW BATTERY]
[BATTERY CHARGER
ERROR]
[DRV ERROR]
[CALIBRATION ERROR]
[MAINTENANCE]
[SENSOR ERROR]
[LED TEMPERATURE HIGH]
POSSIBLE CAUSES
DMX Signal is present when using TRANSFER CONFIG
TEMPERATURE is out of standard temperature range use
(minus or plus)
Recharge the main battery, keeping the product under
charge for some hours.
If the error still occurrs, the battery is faulty.
Replace the battery.
Battery is almost empty (20%). Need to recharge
Battery charger circuit not working
Communication failure between DISP and DRV
Communication failure between calibration chip and DRV2
or Calibration returning unexpected/wrong datas
The maintenance time exceeds the set maintenance time
Sensor damaged (open or in short circuit)
This error message indicates that an overheating on the
lamp has occurred and the lamp has been switched OFF by
the product protection system.
PROLIGHTS - Smart BatPlusNeo
function
CODE ERROR
1
2
3
4
5
6
7
8
9
10
11
29