17 - ERROR MESSAGES

The error is shown on the unit display. In the table below, the "ERROR SHOWED ON SCREEN" column
lists the possible errors, accompanied by a possible cause ("POSSIBLE" CAUSES "column).
The color of the error messages (listed in the "COLOR MESSAGES" column) is different for each board
it refers to ("PCB" column).
On page 33 you can see the location of the various pcb boards with their respective error colors.
ERROR SHOWED ON
SCREEN
[PAN/TILT PCB ERROR]
[PAN MOTOR ERROR]
[TILT MOTOR ERROR]
[PAN SENSOR ERROR]
[TILT SENSOR ERROR]
[FAN PCB ERROR]
[LED TEMP. SENSOR
ERROR]
[LEFT AIR IN FAN ERR.]
[RIGHT AIR OUT FAN
ERR.]
POSSIBLE CAUSES
Pan tilt pcb not detected.
This message will appear after the reset of the product if:
the PAN magnetic-indexing circuit detect a failure (sensor
failed or magnet is missing).
or the stepping motor is defective.
or its driving IC on the PCB is defective.
or the product is not located in the default position after the
reset of the fixture.
This message will appear after the reset of the product if:
the TILT magnetic-indexing circuit detect a failure (sensor
failed or magnet is missing) .
or the stepping motor is defective.
or its driving IC on the PCB is defective.
or the product is not located in the default position after the
reset of the fixture.
Pan sensor not detecteld.
Tilt sensor not detecteld.
Fan PCB not detected.
LAMP sensor damaged (open or in short circuit).
Air in blower for cooling the lamp failed, the lamp has been
switched OFF.
Air out blower for cooling the lamp failed, the lamp has
been switched OFF.
PROLIGHTS - Jet Hybrid200
POSSIBLE PCB
WITH ANOMALY
2U
2U
2U
2U
2U
3U
3U
3U
3U