CETECOM Inc.
Test report no.:EMC_381EN489-17_2002
IMMUNITY TEST:
RADIATED, RF ELECTROMAGNETIC FIELDS
According to EMC basic standard (EN 61000-4-3[9])
· The distance between the turn-table axis and TX-antenna is 3m.
· Field strength = 3V/m
· Start Frequency = 80MHz
· Frequency Step = lin 1MHz
· Modulation = AM, 1KHz, 80%
Failure Criteria
Describe applicable failure criteria for EUT
Example
1.Continuous data transfer between EUT and Mini PCI Access Point
2.Transmitting following data: 65 bytes from 192.168.1.1 icmp_seg = xxx + H = 255 time = xxx
3.If connection drops then the the program will display "Request Timed out"
Failure Criteria obesrved
Describe how failure criteria was observed
Example
1. Observe continuous scrolling "# " on the screen
Plot
Antenna
no.
Polarity
5.1
vertical
5.2
horizontal
Performance criteria A observed
Issue date:2003-01-10
Stop Frequency = 1000MHz
Radiation to
Front
Front
Page 13 (25)
Reaction of the EUT
During and after test
No reactions recognized
No reactions recognized
Result
passed
passed
Need help?
Do you have a question about the F5D7010CE2 and is the answer not in the manual?