CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 2 (33) Table of Contents General information Notes Testing laboratory Details of applicant Application details Test item Test standards Technical test Summary of test results Test report General information Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM Inc.
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 3 (33) Details of applicant Name Broadcom corporation Street 190 Mathilda Place City / Zip Code Sunnyvale, 94086 Country Contact Chris McGough Telephone 408-922-5810 Tele-fax 408-543-3399 e-mail cmcgough@broadcom.com Application details Date of receipt of application 2002-12-16 Date of receipt test item 2002-11-21...
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 4 (33) Technical test Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests Performed Final Verdict: Passed (only “passed” if all single measurements are “passed”) Technical responsibility for area of testing: 2003-01-10 EMC &...
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 5 (33) Test report TEST REPORT Test report no. : EMC_381EN328_2002 (BCM94306CB)
Page 6
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 6 (33) TEST REPORT REFERENCE LIST OF MEASUREMENTS PAGE EFFECTIVE ISOTROPIC RADIATED POWER CLAUSE 5.2.1 PEAK POWER DENSITY CLAUSE 5.2.2 FREQUENCY RANGE CLAUSE 5.2.3 SPURIOUS EMISSIONS CLAUSE 5.2.4 RECEIVER SPURIOUS EMISSIONS CLAUSE 5.3.2 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS PHOTOGRAPHS BLOCK DIAGRAMS...
Page 7
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 7 (33) EFFECTIVE ISOTROPIC RADIATED POWER CLAUSE 5.2.1 EIRP is calculated by method described under sub clause 7.2.1.2, using following formulae; P = A + G + 10 log (1/x); Where; A = Average power (measured) Freq.(MHz) Average Power measured using wide band Power meter (dBm) 2412...
Page 8
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 8 (33) EFFECTIVE ISOTROPIC RADIATED POWER CLAUSE 5.2.1 TEST CONDITIONS TRANSMITTER POWER (dBm) EIRP Low frequency Mid frequency High frequency 2412MHz 2442MHz 2472MHz ( 23 ) (3.3) 15.14 15.64 15.64 ( 0 ) (3.3) 15.15 16.09...
Page 9
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 9 (33) PEAK POWER DENSITY CLAUSE 5.2.2 For DSSS Systems TEST CONDITIONS Peak Power Density (dBm/MHz) Low frequency Mid frequency High frequency 2412MHz 2442MHz 2472MHz 8.04 9.35 8.22 ( 23 ) (3.3) ≤-20dBW/MHz (10dBm/MHz) Under normal test conditions only...
Page 10
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 10 (33) PEAK POWER DENSITY CLAUSE 5.2.2 Lowest Channel: 2412MHz Notes: -51.96 dBm/Hz is added with 60dB to compensate for the dBm/MHz, therefore 8.04dBm/MHz.
Page 11
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 11 (33) PEAK POWER DENSITY CLAUSE 5.2.2 Mid Channel: 2442MHz Notes: -50.57 dBm/Hz is added with 60dB to compensate for the dBm/MHz, therefore 9.35dBm/MHz.
Page 12
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 12 (33) PEAK POWER DENSITY CLAUSE 5.2.2 Highest Channel: 2472MHz Notes: -51.78 dBm/Hz is added with 60dB to compensate for the dBm/MHz, therefore 8.22dBm/MHz.
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 13 (33) FREQUENCY RANGE CLAUSE 5.2.3 For DSSS Systems FREQUENCY (MHz) at which –80dBm/Hz occurs TEST CONDITIONS Low Frequency (f High Frequency (f 2412 MHz 2472MHz ( 23 ) (3.3) 2403MHz 2481MHz ( 0 ) (3.3) 2404MHz...
Page 14
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 14 (33) FREQUECY RANGE CLAUSE 5.2.3 Lowest Channel: 2412MHz Temp.:23 C Voltage:3.3Vdc...
Page 15
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 15 (33) FREQUECY RANGE CLAUSE 5.2.3 Highest Channel: 2472MHz Temp.:23 C Voltage:3.3Vdc...
Page 16
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 16 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 (Radiated) Transmitter operating NOTE: 1. Measurements were done on low & high channels, but plots depicting the worst case are submitted in the test report. 2. The spurious emissions were done with different settings, using the relevant pre-amplifiers for the relevant frequency ranges.
Page 17
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 17 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ lowest frequency (2412MHz) 30MHz – 1GHz Marker: 455.711423 MHz -59.84 dBm Level [dBm] -100 -110 100M 200M 300M 500M 700M Frequency [Hz]...
Page 18
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 18 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ lowest frequency (2412MHz) 1GHz – 7GHz Notes: Marked frequency is the carrier @ 2412MHz. Marker: 2.418837675 GHz -4.23 dBm Level [dBm] Frequency [Hz]...
Page 19
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 19 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ lowest frequency (2412MHz) 7GHz – 12.75GHz Marker: 7.414829659 GHz -46.96 dBm Level [dBm] -100 12.75G Frequency [Hz]...
Page 20
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 20 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ highest frequency (2472MHz) 30MHz-1GHz Marker: 397.39479 MHz -60.82 dBm Level [dBm] -100 -110 100M 200M 300M 500M 700M Frequency [Hz]...
Page 21
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 21 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ highest frequency (2472MHz) 1GHz – 7GHz Notes: Marked frequency is the carrier @ 2472MHz. Marker: 2.466933868 GHz -4.16 dBm Level [dBm] Frequency [Hz]...
Page 22
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 22 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 Transmitter operating @ highest frequency (2472MHz) 7GHz – 12.75GHz Marker: 7.414829659 GHz -46.96 dBm Level [dBm] -100 12.75G Frequency [Hz]...
Page 23
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 23 (33) SPURIOUS EMISSIONS CLAUSE 5.2.4 (Radiated) Transmitter Standby NOTE: Plots under section Receiver spurious emissions are valid for this section also. Lowest Frequecy Highest Frequecy Band- Level Band- Level (MHz) width (dBm) (MHz) width...
Page 24
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 24 (33) RECEIVER SPURIOUS EMISSIONS CLAUSE 5.3.2 (Radiated) NOTE: 1. Measurements were done on low & high channels, but plots depicting the worst case are submitted in the test report. 2. The receiver spurious emissions were done with different settings, using the relevant pre-amplifiers for the relevant frequency ranges.
Page 25
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 25 (33) RECEIVER SPURIOUS EMISSIONS CLAUSE 5.3.2 30MHz – 1GHz Marker: 133.026052 MHz -66.19 dBm Level [dBm] -100 -110 100M 200M 300M 500M 700M Frequency [Hz]...
Page 26
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 26 (33) RECEIVER SPURIOUS EMISSIONS CLAUSE 5.3.2 1GHz – 7GHz Marker: 1.276553106 GHz -66.44 dBm Level [dBm] -100 Frequency [Hz]...
Page 28
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 28 (33) TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS Instrument/Ancillary Type Manufacturer Serial No. Spectrum Analyzer ESIB 40 Rohde & Schwarz 100107 Spectrum Analyzer FSEM 30 Rohde & Schwarz 826880/010 Signal Generator SMY02 Rohde &...
Page 29
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 29 (33) PHOTOGRAPHS Radiated Measurement Setup Conducted Measurement...
Page 30
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 30 (33) EUT (Top - shielded) EUT (Bottom - shielded)
Page 31
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 31 (33) EUT (Top – unshielded) EUT (Bottom – unshielded)
Page 32
CETECOM Inc. Test report no.:EMC_381EN328-2002 Issue date:2003-01-10 Page 32 (33) BLOCK DIAGRAMS Conducted Testing POWER SPECTRUM METER ANALYZER...