CETECOM Inc.
Test report no.:EMC_381EN489-17_2002
SUMMARY OF TEST RESULTS
EMISSION (EMI)
EMI
Phenomenon
Conducted
Interference voltage,
AC Mains
0.15 – 30*MHz
Radiated
Interference Field
Enclosure
Strength
30 – 1000*MHz
Harmonic Current
AC mains
Emissions
input port
Flicker & Voltage
AC mains
Fluctuation
input port
IMMUNITY (EMS)
EMS
Phenomenon
Electrostatic
discharge
Enclosure
(ESD)
RF-electro-magnetic
Enclosure
field
Fast transients,
Powerline
BURST
AC / DC
Powerline
Surge
(1 phase)
Transients & Surges
Powerline
vehicular
evironment
charger)
Powerline
RF Common mode
signal lines
Vol. Dips,
interruptions &
output AC
fluctuations (AC
ports only
Power)
na=not applicable
Issue date:2003-01-10
Port
Requirements
Standard
ETSI EN 301 489-1,
2000-08
Chap. 8.4
ETSI EN 301 489-1,
2000-08
Chap. 8.2
ETSI EN 301 489-1,
2000-08
Chap. 8.5
ETSI EN 301 489-1,
2000-08
Chap. 8.6
Port
Requirements
Standard
ETSI EN 301 489-1,
2000-08
Chap. 9.3
--
ETSI EN 301 489-1,
2000-08
Chap. 9.2
--
ETSI EN 301 489-1,
2000-08
Chap. 9.4
--
ETSI EN 301 489-1,
2000-08
Chap. 9.8
--
ETSI EN 301 489-1,
2000-08
(car
Chap. 9.6
--
ETSI EN 301 489-1,
2000-08
AC/DC
Chap. 9.5
--
ETSI EN 301 489-1,
Input &
2000-08
Chap. 9.7
--
EUT set-
up
Basic standard
EN 55022:1998
na
+Corr.2001 + A1:2000
EN 55022:1998
na
+Corr.2001 + A1:2000
EN 61000-3-2: 2000
na
EN 61000-3-3: 2000
na
EUT set-
up
Basic standard
EN 61000-4-2: 1995
na
+A1: 1998+A2:2001
EN 61000-4-3: 1996
na
+A1: 1998+A2:2001
EN 61000-4-4: 1995
na
+A1: 2001
EN 61000-4-5: 1995
na
+A1: 2001
ISO 7637-1/2:1990
na
(12/24VDC)
EN 61000-4-6: 1996
na
+A1: 2001
EN 61000-4-11: 1994
na
+A1: 2001
Page 7 (25)
Result
Applicability
Complies
Not Applicable
Complies
Applicable
Complies
Not Applicable
Complies
Not Applicable
Result
Applicability
Complies
Applicable
Complies
Applicable
Complies
Not Applicable
Complies
Not Applicable
Complies
Not Applicable
Complies
Not Applicable
Complies
Not Applicable
Need help?
Do you have a question about the F5D7010CE2 and is the answer not in the manual?