CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 2 (25) Table of Contents General information Notes Testing laboratory Details of applicant Application details Test item Test standards Technical test Summary of test results Test report General information Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM Inc.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 3 (25) Details of applicant Name Broadcom corporation Street 190 Mathilda Place City / Zip Code Sunnyvale, 94086 Country Contact Chris McGough Telephone 408-922-5810 Tele-fax 408-543-3399 e-mail cmcgough@broadcom.com Application details Date of receipt of application 2002-12-19 Date of receipt test item 2002-11-21...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 4 (25) Technical test Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests Performed Final Verdict: Passed (only “passed” if all single measurements are “passed”) Technical responsibility for area of testing: 2003-01-10 EMC &...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 5 (25) Test report TEST REPORT Test report no. : EMC_381EN489-17_2002 (BCM94306CB)
Page 6
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 6 (25) SUMMARY OF TEST RESULTS EMISSION (EMI) IMMUNITY (EMS) GENERAL PERFORMANCE CTIRERIA EMISSION TEST: RADIATED EMISSIONS AC LINE CONDUCTED EMISSIONS HARMONIC CURRENT EMISSIONS FLICKER AND VOLTAGE FLUCTUATION IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS RF COMMON MODE ELECTROSTATIC DISCHARGE FAST TRANSIENTS COMMON MODE...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 7 (25) SUMMARY OF TEST RESULTS EMISSION (EMI) Port Requirements EUT set- Result Applicability Phenomenon Standard Basic standard Conducted ETSI EN 301 489-1, EN 55022:1998 Interference voltage, AC Mains 2000-08 Complies Not Applicable +Corr.2001 + A1:2000 0.15 –...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 8 (25) GENERAL PERFORMANCE CRITERIA The performance criteria are: -performance criteria A for immunity tests with phenomena of a continuous nature; Communication between the BCM94306CB and BCM94306MP in the form of pings should not drop during the test.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 9 (25) EMISSION TEST: RADIATED EMISSIONS This test assessses the ability of ancilliary equipment to limit their internal noise from being radiated from the enclosure. According to EMC basic standard (EN 55022) Measurement according to EMC basic standard, but performed in the anechoic chamber with a reduced measuring distance of 3m.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 10 (25) AC LINE CONDUCTED EMISSIONS According to EMC basic standard (EN 55022 [7] Class-B) 1.For the table top EUT the distance to the reference ground plane (wall) should be 40 cm. 2.AC input line plugged into LISN EUT Operating mode Tx at middle.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 11 (25) HARMONIC CURRENT EMISSIONS This test was performed as per EMC Basic Standard EN 61000-3-2(Dec-2000) EUT Operating mode Tx at middle. channel Plot No. Port EUT operating mode or Result operating mode no. (passed / failed ) AC input Tx at mid.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 12 (25) FLICKER AND VOLTAGE FLUCTUATION This test was performed as per EMC Basic Standard EN 61000-3-3 EUT Operating mode Tx at middle. channel Plot No. Port EUT operating mode or Result operating mode no.
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 13 (25) IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS According to EMC basic standard (EN 61000-4-3[9]) · The distance between the turn-table axis and TX-antenna is 3m. · Field strength = 3V/m · Start Frequency = 80MHz Stop Frequency = 1000MHz ·...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 14 (25) RF COMMON MODE According to EMC basic standard (EN 61000-4-6[10]) Start Frequency = 150KHz Stop Frequency = 80MHz Frequency Step = 50KHz in the range of 150KHz – 5MHz 1% increment in the range of 5MHz – 80MHz Field strength = 3V/m Modulation = AM, 1KHz, 80% Test setup...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 15 (25) ELECTROSTATIC DISCHARGE According to EMC basic standard (EN 61000-4-2[10]) For the table top EUT the distance to the reference ground plane should be 80 cm. Direct contact discharge on conducting surfaces of EUT Indirect air discharge on insulating surfaces of EUT ±2kV, ±4kV direct discharge &...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 16 (25) FAST TRANSIENTS COMMON MODE According to EMC basic standard (EN 61000-4-4[11]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.The test level for ac mains power input ports shall be 1KV open curcuit. Test setup Burst on Power Line (direct injection) Failure Criteria...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 17 (25) SURGES COMMON & DIFFERENTIAL MODE (1-phase) According to EMC basic standard (EN 61000-4-5[14]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.1KV open circuit for common mode & 0.5KV open circuit for differential mode. Failure Criteria Failure Criteria obesrved 5 pulses for each polarity and test voltage, alternating negative/positive, triggered in case of AC-powerline: 0°, 45°, 90°, 180°,...
CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 18 (25) VOLTAGE DIPS According to EMC basic standard (EN 61000-4-11 [13]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.The test level shall be – a vol. Reduction of the supply vol. of 30% for 10ms; 60% for 100ms and >95% for 5000ms Failure Criteria Failure Criteria obesrved...