Broadcom F5D7010CE2 Test Report
Broadcom F5D7010CE2 Test Report

Broadcom F5D7010CE2 Test Report

54g wireless lan cardbus pc card

Advertisement

Quick Links

CETECOM Inc.
.
CETECOM Inc
411 Dixon Landing Road, Milpitas, CA-95035, USA
Phone: +1 408 586 6200
Fax: +1 408 586 6299
www.cetecom.com
Issued test report consists of 25 Pages
Page 1 (25)
FCC LISTED, REG. NO.: 101450
&
RECOGNIZED BY INDUSTRY CANADA
IC – 3925
Test report no.: EMC_381EN489-17_2002
ETSI EN 301 489-17 V1.1.1 (2000-09)
(BCM94306CB)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F5D7010CE2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Broadcom F5D7010CE2

  • Page 1 CETECOM Inc. CETECOM Inc 411 Dixon Landing Road, Milpitas, CA-95035, USA Phone: +1 408 586 6200 Fax: +1 408 586 6299 www.cetecom.com Issued test report consists of 25 Pages Page 1 (25) FCC LISTED, REG. NO.: 101450 & RECOGNIZED BY INDUSTRY CANADA IC –...
  • Page 2: Table Of Contents

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 2 (25) Table of Contents General information Notes Testing laboratory Details of applicant Application details Test item Test standards Technical test Summary of test results Test report General information Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM Inc.
  • Page 3: Details Of Applicant

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 3 (25) Details of applicant Name Broadcom corporation Street 190 Mathilda Place City / Zip Code Sunnyvale, 94086 Country Contact Chris McGough Telephone 408-922-5810 Tele-fax 408-543-3399 e-mail cmcgough@broadcom.com Application details Date of receipt of application 2002-12-19 Date of receipt test item 2002-11-21...
  • Page 4: Technical Test

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 4 (25) Technical test Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests Performed Final Verdict: Passed (only “passed” if all single measurements are “passed”) Technical responsibility for area of testing: 2003-01-10 EMC &...
  • Page 5: Test Report

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 5 (25) Test report TEST REPORT Test report no. : EMC_381EN489-17_2002 (BCM94306CB)
  • Page 6 CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 6 (25) SUMMARY OF TEST RESULTS EMISSION (EMI) IMMUNITY (EMS) GENERAL PERFORMANCE CTIRERIA EMISSION TEST: RADIATED EMISSIONS AC LINE CONDUCTED EMISSIONS HARMONIC CURRENT EMISSIONS FLICKER AND VOLTAGE FLUCTUATION IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS RF COMMON MODE ELECTROSTATIC DISCHARGE FAST TRANSIENTS COMMON MODE...
  • Page 7: Summary Of Test Results

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 7 (25) SUMMARY OF TEST RESULTS EMISSION (EMI) Port Requirements EUT set- Result Applicability Phenomenon Standard Basic standard Conducted ETSI EN 301 489-1, EN 55022:1998 Interference voltage, AC Mains 2000-08 Complies Not Applicable +Corr.2001 + A1:2000 0.15 –...
  • Page 8: General Performance Ctireria

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 8 (25) GENERAL PERFORMANCE CRITERIA The performance criteria are: -performance criteria A for immunity tests with phenomena of a continuous nature; Communication between the BCM94306CB and BCM94306MP in the form of pings should not drop during the test.
  • Page 9: Emission Test

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 9 (25) EMISSION TEST: RADIATED EMISSIONS This test assessses the ability of ancilliary equipment to limit their internal noise from being radiated from the enclosure. According to EMC basic standard (EN 55022) Measurement according to EMC basic standard, but performed in the anechoic chamber with a reduced measuring distance of 3m.
  • Page 10: Ac Line Conducted Emissions

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 10 (25) AC LINE CONDUCTED EMISSIONS According to EMC basic standard (EN 55022 [7] Class-B) 1.For the table top EUT the distance to the reference ground plane (wall) should be 40 cm. 2.AC input line plugged into LISN EUT Operating mode Tx at middle.
  • Page 11: Harmonic Current Emissions

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 11 (25) HARMONIC CURRENT EMISSIONS This test was performed as per EMC Basic Standard EN 61000-3-2(Dec-2000) EUT Operating mode Tx at middle. channel Plot No. Port EUT operating mode or Result operating mode no. (passed / failed ) AC input Tx at mid.
  • Page 12: Flicker And Voltage Fluctuation

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 12 (25) FLICKER AND VOLTAGE FLUCTUATION This test was performed as per EMC Basic Standard EN 61000-3-3 EUT Operating mode Tx at middle. channel Plot No. Port EUT operating mode or Result operating mode no.
  • Page 13: Immunity Test

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 13 (25) IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS According to EMC basic standard (EN 61000-4-3[9]) · The distance between the turn-table axis and TX-antenna is 3m. · Field strength = 3V/m · Start Frequency = 80MHz Stop Frequency = 1000MHz ·...
  • Page 14: Rf Common Mode

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 14 (25) RF COMMON MODE According to EMC basic standard (EN 61000-4-6[10]) Start Frequency = 150KHz Stop Frequency = 80MHz Frequency Step = 50KHz in the range of 150KHz – 5MHz 1% increment in the range of 5MHz – 80MHz Field strength = 3V/m Modulation = AM, 1KHz, 80% Test setup...
  • Page 15: Electrostatic Discharge

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 15 (25) ELECTROSTATIC DISCHARGE According to EMC basic standard (EN 61000-4-2[10]) For the table top EUT the distance to the reference ground plane should be 80 cm. Direct contact discharge on conducting surfaces of EUT Indirect air discharge on insulating surfaces of EUT ±2kV, ±4kV direct discharge &...
  • Page 16: Fast Transients Common Mode

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 16 (25) FAST TRANSIENTS COMMON MODE According to EMC basic standard (EN 61000-4-4[11]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.The test level for ac mains power input ports shall be 1KV open curcuit. Test setup Burst on Power Line (direct injection) Failure Criteria...
  • Page 17: Surges Common & Differential Mode (1-Phase)

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 17 (25) SURGES COMMON & DIFFERENTIAL MODE (1-phase) According to EMC basic standard (EN 61000-4-5[14]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.1KV open circuit for common mode & 0.5KV open circuit for differential mode. Failure Criteria Failure Criteria obesrved 5 pulses for each polarity and test voltage, alternating negative/positive, triggered in case of AC-powerline: 0°, 45°, 90°, 180°,...
  • Page 18: Voltage Dips

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 18 (25) VOLTAGE DIPS According to EMC basic standard (EN 61000-4-11 [13]) 1.For the table top EUT the distance to the reference ground plane should be 80 cm. 2.The test level shall be – a vol. Reduction of the supply vol. of 30% for 10ms; 60% for 100ms and >95% for 5000ms Failure Criteria Failure Criteria obesrved...
  • Page 19: Plots

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 19 (25) PLOTS Plot 1.1 Marker: 455.711423 MHz 33.24 dBµV/m Level [dBµV/m] 100M 200M 300M 500M 700M Frequency [Hz]...
  • Page 20 CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 20 (25) Plot 5.1 Polarization: Vertical Marker: 1 GHz EUT Nogo [-] -0.5 80M 100M 200M 300M 400M 500M600M 800M 1G Frequency [Hz] Marker: 3.018376 Immunity Level [V/m] 80M 100M 200M 300M 400M 500M600M 800M 1G Frequency...
  • Page 21 CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 21 (25) Plot 5.2 Polarization: Horizontal Marker: 1 GHz EUT Nogo [-] -0.5 80M 100M 200M 300M 400M 500M600M 800M 1G Frequency [Hz] Marker: 1 GHz 2.965052 V/m Immunity Level [V/m] 80M 100M 200M 300M 400M 500M600M...
  • Page 22: Test Equipment And Ancillaries Used For Tests

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 22 (25) TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS Instrument/Ancillary Manufacturer Type/Model Serial No. Spectrum Analyzer Rohde & Schwarz ESIB 40 100107 Digital Radio Comm. Tester Rohde & Schwarz CMU 200 101821 Harmonic / Flicker tester Voltech 304644...
  • Page 23 CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 23 (25) Instrument/Ancillary Manufacturer Type/Model Serial No. Log periodic Antenna EMCO 3148 1186 Log periodic Antenna EMCO 3148 1187 Biconical Antenna EMCO 3109 0005-3250 Biconical Antenna EMCO 3110B 0004-3356 Biconical Antenna EMCO 3110B 0004-3357 Biconilog Antenna...
  • Page 24: Photographs

    CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 24 (25) PHOTOGRAPHS Radiated Immunity Radiated Emissions...
  • Page 25 CETECOM Inc. Test report no.:EMC_381EN489-17_2002 Issue date:2003-01-10 Page 25 (25)

This manual is also suitable for: