Dell 53-1002116-01 Administrator's Manual page 127

Dell network card user manual
Table of Contents

Advertisement

TABLE 23
CoS
3
4
5
6
7
Creating a CEE map
Only a single CEE map is allowed, which is created automatically with the name "default." You are
not be able to delete or rename this map.
To create a CEE map, perform the following steps from Privileged EXEC mode.
1. Enter global configuration mode.
2. Create a CEE map.
3. Enter the copy command to save the running-config file to the startup-config file.
Defining a priority group table
To define a priority group table map, perform the following steps from Privileged EXEC mode.
1. Enter global configuration mode.
2. Specify the name of the CEE map to define. In this example 'test' is used.
3. Define the CEE map for PGID 0.
4. Define the CEE map for PGID 1.
5. Enter the copy command to save the running-config file to the startup-config file.
Dell Converged Enhanced Ethernet Administrator's Guide
53-1002116-01
Default CEE priority table (Continued)
PGID
15.4
15.3
15.2
15.1
15.0
switch#configure terminal
switch(config)#cee-map default
The following example creates a CEE map enter CEE-Map CLI configuration submode.
switch:admin>cmsh
switch>enable
switch#configure terminal
Enter configuration commands, one per line.
switch(config)#cee-map default
switch(config)#end
switch#copy running-config startup-config
switch#configure terminal
switch(config)#cee-map default
switch(config-ceemap)#priority-group-table 0 weight 50 pfc
switch(config-ceemap)#priority-group-table 1 weight 50
switch#copy running-config startup-config
Converged Enhanced Ethernet map configuration
End with CNTL/Z.
10
109

Advertisement

Table of Contents
loading

Table of Contents