ACK
7FH 60H
85.MULTI •i SPRIT•j REPEAT TIMER SET
Function
External control apparatus sets "multi (sprit) screen repeat timer" of a plasma
monitor.
Transmission Data
DFH 80H 60H 34H 09H
DATA00 REPEAT TIMER 00H:OFF
REPEAT1
DATA01 MULTI MODE
DATA02 INPUT1•iLeft or main•j
DATA03 INPUT2(Right or Sub)
0DH : HD3(SCART3)
80H
33H
DATA00•`DATA03 CKS
01H:ON
00H : SINGLE
01H : Side By Side1(Same Size Screen)
02H : Side By Side2(Left Screen Smaller)
03H : Side By Side2(Left ScreenBigger)
04H : Picture in Picture1(Sub Screen Bottom Left)
05H : Picture in Picture2(Sub Screen Bottom Right)
06H : Picture in Picture3(Sub Screen Top Right)
07H : Picture in Picture4(Sub Screen Top Left)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
00H
CKS