25. H-WIDTH Gain Data
Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : H-WIDTH Gain Flag
DATA02 : H-WIDTH Gain
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: H-WIDTH Gain Flag
26. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
01H : OFF
ACK
7FH 60H 80H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
01H : OFF
DATA01
03H
08H
00H : 0
:
40H : +64
DATA01
03H
08H
DATA01 DATA02 CKS
03H
09H
DATA01 DATA02 CKS
03H
09H
26
DATA02
CKS
CKS