55.PRESENT TIME SETTING
Function
External control apparatus sets up the present time of a plasma monitor.
Transmission Data
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS
DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday)
DATA01 HOUR
DATA02 minutes 00H-09H:00-09
ACK
7FH 60H 80H 31H 00H CKS
56.MULTI MODE Select
Function
External control apparatus changes MULTI MODE of a plasma monitor.
Transmission Data
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
00H-09H:00-09
10H~19H:10~19
20H~23H:20~23
10H~19H:10~19
20H~29H:20~29
30H~39H:30~39
40H~49H:40~49
50H~59H:50~59