07. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the
plasma c
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CONTRAST Gain Flag
DATA02 : CONTRAST Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: CONTRAST Gain Flag
08. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BRIGHT Gain Flag
DATA02 : BRIGHT Gain
ACK
7FH 60H 80H 7FH 02H DATA00
01H
07H
CCH : -52
:
FFH : -01
00H : 0
01H : +01
:
14H : +20
01H
07H
01H
08H
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
DATA01
14
CKS

Hide quick links: