03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH 80H 60H 47H 01H DATA00
DATA00 : Input Select
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 47H 00H CKS
CKS
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2(DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)