Error Code
Test
Description
4800
to
480FH
RAM test
128k bank 4 dO-d3
4810
to
48FOH
RAM test
128k bank 4 d4-d7
4900
to
490FH
RAM test
128k bank 4 d8-d 11
4910
to
49FOH
RAM test
128k bank 4 d12-d15
5000
to
5FFFH
Reserved for Manufacturing test.
6100
to
6113H
RAM test
Address line defined by the last 2 digits
failed. (Hex) i.e. 6111
=
address line 11 h
=
a17 failed.
7100
to
71FFH
8259 test
Master 8259 failed.
7200
to
72FFH
8259 test
Industry Standard (STD) slave failed.
7300
to
73FFH
8259 test
HP slave failed.
7400H
8259 test
Master 8259 failed.
7500H
8259 test
Industry Standard (STD) slave failed.
7500H
8259 test
HP slave failed.
8000
to
82FFH
Reserved for manufacturing test.
8300
to
83FFH
Hard disc
Controller/drive failed.
8400
to
8FFFH
Reserved for manufacturing test.
9001
to
91FFH
Flexible Disc
Flexible disc controller problem.
9200
to
9FFFH
Reserved for manufacturing test.
A002
to
AOOFH
80287 co-proc.
Internal problem with 287.
B001
to
B007H
Multimode
Video adapter problem.
B008H
Multimode
Video adapter RAM problem.
COOO
to
CFFFH
Extended RAM
Extended RAM failure.
Where: OCOOO to OCOFFH
= >
even byte is bad
OC100 to OC1 FFH
=
>
odd byte is bad.
xxOO to xxFEH
=
>
bad RAM at address
00* 1OOOOH to OFE* 1OOOOH
example: if error
=
OC 124H then:
1
=
>
odd byte is bad.
24
=
>
error is in 128K bank starting at address:
024H * 1OOOOH
=
0240 OOOH
if error
=
OCOF1 H then:
a
=
>
even byte is bad.
F1
=
>
error is in 128K bank starting at address:
OF1H*10000H
=
OF10 OOOH
00000
to
OFF FFH Reserved for manufacturing test.
System Processes