Table 10.2
Diagnostic Error Codes Displayed by POST
Error Code
Test
Description
0001
to
OOOFH
80286 chip
80286 chip failed.
0010
ROM checksum
ROM a fails checksum test.
0011
ROM checksum
ROM 1 fails checksum test.
0110
to
012FH
RTC test
Real-time clock failed.
0200
to
02FFH
CMOS test
Real-time clock failed.
0300
to
037FH
8041 test
8041 keyboard controller failed.
0401
System error.
Could not set A2a line.
1000
to
12FFH
Timer chip test
Timer chip failed
2110
to
211 FH
DMA test
DMA chip 1 failed.
2120
to
212FH
DMA test
DMA chip 2 failed.
2131H
DMA test
DMA chip 1 failed.
2132H
DMA test
DMA chip 2 failed.
2210
to
2217H
DMA test
Page register failed.
3000
to
30FFH
HP-HIL controller
HP-HIL controller failed.
4000
to
400FH
RAM test
128k bank 0 dO-d3
4010
to
40FOH
RAM test
128k bank a d4-d7
4100
to
410FH
RAM test
128k bank 0 d8-d 11
4110
to
41FOH
RAM test
128k bank 0 d 12-d 15
4200
to
420FH
RAM test
128k bank 1 dO-d3
4210
to
42FOH
RAM test
128k bank 1 d4-d7
4300
to
430FH
RAM test
128k bank 1 d8-d 11
4310
to
43FOH
RAM test
128k bank 1 d12-d15
4400
to
440FH
RAM test
128k bank 2 dO-d3
4410
to
44FOH
RAM test
128k bank 2 d4-d7
4500
to
450FH
RAM test
128k bank 2 d8-d 11
4510
to
45FOH
RAM test
128k bank 2 d12-d15
4600
to
460FH
RAM test
128k bank 3 dO-d3
4610
to
46FOH
RAM test
128k bank 3 d4-d7
4700
to
47·0FH
RAM test
128k bank 3 d8-d 11
4710
to
47FOH
RAM test
128k bank
3
d12-d15
318