Functional Extensions
Operating Guide
Table 17: Technical Specifications for Relay Option OC7R0
Functions
Number of relay outputs
Maximum terminal load (AC-1): Resistive load
Maximum terminal load (AC-15): Inductive load
@ cos =0.4
Maximum terminal load (DC-1): Resistive load
Maximum terminal load (DC-13) : Inductive load
Minimum load
Rated number of cycles (@2 A resistive load)
Cable type
Cable size
Maximum cable length
Maximum altitude
Ambient temperature
Weight
Environment
6.6 Setup and Connection Examples for Relay Option OC7R0
X101
X102
1
2
3
4
5
6
Illustration 16: Wiring Configuration for Relay Option OC7R0
Danfoss A/S © 2022.12
Data
3 (2 NO/NC, 1 NO)
250 V AC, 2 A
250 V AC, 0.2 A
80 V DC, 2 A
24 V DC, 0.1 A
24 V DC, 10 mA
24 V AC, 20 mA
400 000 switchings
Cu, 75 °C (167 °F)
Solid: 0.2–2.5 mm
Flexible: 0.2–2.5 mm
Flexible with ferrule, without plastic sleeve: 0.25–2.5 mm
Flexible without ferrule, with plastic sleeve: 0.25–2.5 mm
300 m (984 ft)
4400 m (14400 ft)
The operating altitude sets requirements on voltages.
-
For the wiring diagrams for different operating altitudes, see
ing Diagrams for Different Operating
-30 °C...60 °C (-22 °F...140 °F)
0.12 kg (0.26 lb)
Overvoltage category III/pollution degree 2
X103
7
8
Relay Option Installation and
2
(24–14 AWG)
2
(24–14 AWG)
N O T I C E
Altitudes.
AQ390830267692en-000501 / 136R0273 | 27
Configuration
2
(24–14 AWG)
2
(24–14 AWG)
6.6.1 Wir-
Need help?
Do you have a question about the iC7 Series and is the answer not in the manual?
Questions and answers