Buzzer Out; Alarm Out - Lorex L20WD800 Series Instruction Manual

20” wide screen lcd monitor with built-in digital video recorder
Hide thumbs Also See for L20WD800 Series:
Table of Contents

Advertisement

Event / Sensor

ALARM OUT

Sends an Alarm Out signal to a device (such
as a Manual Door or independent Light/
Buzzer Alarm) when an Alarm In event is
detected
• Channel - Indicates all channels.
• Operation - Setup Relay Connect with
Alarm Sensor to either Enable or
Disable. Must be ENABLED to change
the settings manually.
• Mode - Setup Reacted Relay as either
Latched or Transparent Mode:
Latched – When sensor alarm activated,
relay reacted in setup duration.
Transparent – Relay reacted temporary
during sensor alarm activate.
• Duration - Sets the Reacted Relay Time.
(5sec~5min or Until key-in)
• Type - Set the Relay Type to either N/O
(Normally Open) or N/C (Normally
Closed).
• HDD Event - Turns the Alarm ON/OFF
when the Hard Drive experiencing
problems.
• CH1~8 Alarm - Sends the Alarm Out
when an Alarm Event is detected (set to
ON/OFF).
• CH 1~8 Video Loss - Sends the Alarm
Out when a Video Loss Event is
detected (set to ON/OFF).
• CH 1~8 Motion - Sends the Alarm Out
when a Motion Event is detected (set to
ON/OFF).
46

BUZZER OUT

Generates a Buzzer when an alarm is
detected.
• Operation - Enables / Disables the buzzer
for selected Event / Alarm types. Set to
ENABLE to change the following settings:
• Mode - Set the Reacted Relay to either
Latched or Transparent Mode.
• HDD Event - Generates a Buzzer alert
when a Hard Drive event occurs (set to
ON/OFF).
• Duration - Sets the Buzzer time (5sec ~
5min or until a user logs into the system).
• Alarm - Generates a Buzzer Alarm when
an Alarm Event is detected (set to ON/
OFF).
• Video Loss - Generates a Buzzer Alarm
when a Video Loss Event is detected
(set to ON/OFF).
• Motion - Generates a Buzzer Alarm
when a Motion Event is detected (set to
ON/OFF).

Advertisement

Table of Contents
loading