Setting In/Out terminals

- ALARM INPUT Terminal
This terminal is to connect PIR sensors, door contacts or
any type of motion detector.
1) "N/C" (Normally CLOSED Switch Circuit)
If the input becomes DC 5V for 500 msec or more,
the VCR starts alarm recording.
2) "N/O" (Normally OPEN Switch Circuit)
If the input becomes 0V for 500 msec or more, the
VCR starts alarm recording.
- TAPE END(OUT) Terminal
1) "High"
During recording, when the end of the tape is
reached, the output becomes DC 5V.
- WARNING OUTPUT Terminal
1) "High"
If the Power LED on the front panel continues to
flash, the output becomes DC 5V. If the POWER
button is pressed, the emergency mode is released,
then the output becomes 0V.
38
Security 14" Monitor Combination
Daily Inspection
The following daily inspections are recommended in
order to assure long-term and trouble-free operation of
the unit.
The daily inspections are particularly important if using
autorepeat recording.
Inspection Procedure
1
Turn on the power to the camera, TV monitor and
other connected devices.
2
Check that the image received on the TV monitor is
correct.
• If the security lock is
engaged, it has to be
3
Check that the on-screen display of the date and time
released before
proceeding with the
is correct.
inspection.
4
Press the REW button to rewind the recorded tape a
• If any problem is
few seconds.
discovered during the
inspection,unplug the
5
Press the PLAY button and check that the playback
power cord and consult
image is correct.
your dealer.
• Check in particular playback of time lapse recording
(18 or 24 hour mode).
6
Check that the recorded date and time are correct.