Kyocera Mita Ecosys FS-1800+ Operation Manual page 55

Kyocera fs-1800+: operation guide
Hide thumbs Also See for Ecosys FS-1800+:
Table of Contents

Advertisement

6
?
7
ENTER
Press the > key. Each time the
item and current setting change as shown below.
>Baud Rate
9600
>Data Bits
8
>Stop Bits
1
>Parity
None
>Protocol
DTR(pos.)&XON
>Barcode Mode
Off
Display the setting item to be changed and press the ENTER key. A
question mark (?) appears.
The following example explains how to change the baud rate. The
settings for other items can be changed in a similar manner.
>Baud Rate
?
9600
1-43
Using the Operator Panel
or
key is pressed, the setting
Definable baud rates: 1200, 2400,
4800, 9600 (default), 19200, 38400,
57600, 115200
Definable data bits: 7, 8 (default)
Definable stop bits: 1 (default), 2
Definable parity: None (default), Odd,
Even, Ignore
Definable protocol: DTR(pos.)&XON
(default), DTP(positive), DTR
(negative), XON/XOFF, ETX/ACK
If set to On when the option barcode
reader is installed, the mode of the
serial interface will be the barcode
mode.

Hide quick links: