Error Number
20
21
22
23
24
25
26
27
28
30
33
34
35
36
37
38
42
43
44
48
49
D–2
Error/Warning Message
NVM token access error
BMC token write error during NVM write
through
Error reading BMC token on upload to
NVM
Error reading BMC first boot token
Primary FIT failed
Secondary FIT failed
PAL_A warning. One copy of PAL is bad
PAL_B warning. Not compatible with CPU Update firmware.
Memory errors detected and PDT is
disabled
Memory required reinterleave to get a
good page 0
One or more memory ranks are
mismatched and deallocated
Memory deallocated because of a loading
error
Memory is not loaded recommended
loading order
The PDT is full
At least one (1) CPU has bad fixed core
ratio
All CPUs were slated for compatibility
deconfig
All CPUs are over clocked
CPU is over clocked
Monarch changed to lowest stepping CPU Only seen once after monarch is
SAL NVM cleared
EFI NVM cleared
Solution
Reflash firmware.
Reflash firmware.
Reflash firmware.
Reseat DIMMs. If error persists,
replace bad DIMM(s).
Load DIMMs in correct loading
order (page 2-12).
Load DIMMs in correct loading
order (page 2-12).
Load DIMMs in correct loading
order (page 2-12).
Clear with pdt clear command in
EFI shell.
set to lowest stepping.
Information only, no action
required.
Information only, no action
required.