D Event, Error And Warning Messages; Efi Error And Warning Messages - HP zx2000 Technical Reference Manual

Hp zx2000: reference guide
Table of Contents

Advertisement

event, error and warning messages
This appendix contains event, error and warning information for the zx2000 system, including:

EFI Error and Warning Messages

IPMI Event Messages
Sensor Data Record Repository (SDRR)
EFI error and warning messages
EFI error and warning messages are displayed on the console as part of the boot process. They
can also be retrieved via the
.
Error Number
2
3
4
7
8
9
10
11
12
13
14
15
16
17
18
19
technical reference guide
info warnings
Error/Warning Message
Insufficient resources to assign to one or
more I/O devices
Failed I/O socket(s) deconfiguration
Unexpected hardware I/O configuration
No BMC installed in platform
BMC cannot be accessed
One or more BMC ports failed
BMC system event log is full
Platform SCR is bad
Set time to BMC SEL failed
SEL get info failed
Initial BMC SEL event failed
Update of BMC buffered data failed
All ACPI BMC ports bad
Read error on BMC token
BMC token transmit checksum error
Error writing BMC token on download
EFI command.
Ensure the BMC ROM is installed;
update BMC firmware.
Check BMC logs for errors.
Clear SEL.
Call support center.
D
Solution
D–1

Advertisement

Table of Contents