power consumption and cooling
The power consumptions listed in the following table are valid for a standard configuration as
shipped (4 GB of memory, 450W power supply, two hard disk drives, and one graphics card).
All information in this section is based on primary power consumptions.
Additional Component
Processor
IDE hard disk drive with I/O access
IDE hard disk without I/O access (idle)
PCI card
AGP card
environmental specifications
Environmental Specifications (System Processing Unit with Hard Disk)
Operating temperature
Storage temperature
Over-temperature shutdown
Operating humidity
Storage humidity
Operating altitude
Storage altitude (long-term)
Operating temperature and humidity ranges may vary depending on the installed mass storage
devices. High humidity levels can cause improper disk operation. Low humidity levels can
aggravate static electricity problems and cause excessive wear of the disk surface.
technical reference guide
130W
443.6 Btu/h
23W
78.4 Btu/h
16W
54.5 Btu/h
10W to 25W
34.12 Btu/h to 85.30 Btu/h
50W (maximum)
170.6 Btu/h
+5° C to +35° C (+41° F to +95° F)
-40° C to +70 C (-40° F to +158° F)
+40° C (+104° F)
15% to 85% relative (non-condensing)
8% to 85% relative (non-condensing)
0-3000 m (0-10,000 ft.)
0-4600 m (0-15,000 ft.)
Product Information
1–5