Appendix C
Command Summary
snmp trap-type enterprise
Syntax Description
Usage Guidelines
78-13124-06
Enables device event trap messages to be sent for a specific trap-type event and
event filter.
snmp trap-type enterprise <config-changed|cpu-utilization|
ssl-total-connections|ssl-tps> [threshold <threshold>] [hysteresis
<lowvalue> <highvalue>]
no snmp trap-type enterprise <config-changed|cpu-utilization|
ssl-total-connections|ssl-tps>
config-changed
cpu-utilization
ssl-total-connections
ssl-tps
threshold <value1>
[<value2>]
Availability: Serial, Telnet; FIPS Mode (serial only)
Cisco 11000 Series Secure Content Accelerator Configuration Guide
Specifies trapping for device configuration changes.
Specifies trapping for CPU utilization levels.
Specifies trapping for total SSL connection levels.
Specifies trapping for SSL transactions per second
levels.
Specifies the threshold option to specify one or more
threshold levels, where appropriate. (Threshold values
are inappropriate for the config-changed option.)
Threshold value1 is the low level and optional
threshold value2 is the high level. Values must be
entered as integers and are inclusive. A device is
considered to be at a low level until the high level
value (value2) is exceeded; a device is considered to
be at a high level until it reaches or exceeds the low
level value (value1). If no threshold values are
specified, the default values are used. If only one
threshold value is specified, it is used as both the high
and low level value; otherwise, two-level thresholding
behavior occurs using the default or user-specified
levels for each value.
Configuration Command Set
C-101