SUPPORTED CONFIGURATIONS
Configuring for CMOS CNV Mode
The hardware changes required to operate in CMOS CNV mode
are as follows:
Remove the 100 Ω termination resistor (RTCNV).
Populate R38 with a 0 Ω resistor to tie CNV− to GND.
Then both the
AD4080
and
CMOS input and output mode, respectively, as follows:
The AD4080 must be configured to accept CMOS level CNV
signaling. Refer to the LVDS_CNV_EN bit in the ADC_DA-
TA_INTF_CONFIG_B register (Register 0x16, Bit 0) in the
AD4080 data sheet for additional details.
The AD9508 OUT2 channel must then be reconfigured for
CMOS level signaling. Refer to Register 0x1F (OUT1 driver)
and Register 0x20 (OUT1 CMOS) of the AD9508 data sheet
for further detail on configuring the output drivers.
analog.com
AD9508
must be configured for
EVAL-AD4080