State
Distance (long field)
Distance (middle field)
Distance (short field)
Error "Waiting for ac-
knowledgment"
Pending error
Initialization
Initialization error
Internal initialization
error
Represen-
Meaning
tation
FXX
Distance
•
F89: Nothing detected (distance ≥ 8.9 m)
•
F0 – F88: Distance to the vehicle in front
in decimeter steps
The distance sensor determines the distance
to the vehicle in front. The reflector is
fastened on the vehicle in front.
bXX
Distance
•
b89: Nothing detected (distance ≥ 8.9 m)
•
b0 – b88: Distance to the vehicle in front
in decimeter steps
The distance sensor determines the distance
to the vehicle in front. The reflector is
fastened on the vehicle in front.
nXX
Distance
•
n89: Nothing detected (distance ≥ 8.9 m)
•
n0 – n88: Distance to the vehicle in front
in decimeter steps
The distance sensor determines the distance
to the vehicle in front. The reflector is
fastened on the vehicle in front.
ErA
Acknowledgeable error. Display switches.
The displayed value range is 0 – 999. For
XXX
further information, refer to chapter "List of
faults" (→ 2 83). To reset errors, switch the
operating switch off.
ErP
Pending error. Display switches. The dis-
played value range is 0 – 999. The errors are
XXX
described in chapter "List of
faults" (→ 2 83).
rbt
The device is restarting.
InI
The device is in the initialization phase.
boo
Device is starting.
IbX
Error during initialization of the device
•
Ib1: reserved
•
Ib2: Device parameter invalid
•
Ib3: "Version" parameter invalid
InE
Internal error during initialization of the
device
Operating Instructions – MOVIPRO
Operation
Status and fault messages
®
PHE..B-A15-.1X0..B-00
8
81
Need help?
Do you have a question about the MOVIPRO PHE B-A15-1X0 B-00 Series and is the answer not in the manual?