Flavor Burst TS BASE SS-2S Operation Manual Supplement

Soft serve system

Advertisement

Quick Links

®
Flavor Burst
Soft Serve System
- Operations Manual Supplement
MODELS: TS BASE SS-2S
TS BASE BEV-2S
TS BASE FCB-2S
Manufactured by
Flavor Burst Company
499 Commerce Drive
Danville, IN 46122
For general information and to locate a
distributor near you, call or visit our website:
Phone: (317) 745-2952
www.flavorburst.com
For pricing, ordering and support, contact
one of our qualified distributors.
NOTE: This booklet is not intended to replace your Operations Manual. It
contains additional information concerning your specific cabinet style only,
but does not contain cleaning, setup and maintenance procedures for the
rest of the system and its parts. Please refer to your new Operations
Manual for this information.
Parts Identification/Function...............................................................................1
Equipment Setup.............................................................................................22
Installing the Sanitizer Line - External Tank..................................................22
Installing the Sanitizer Line - Internal Tank...................................................23
Accessing the Touchscreen Board..............................................................25
Assigning Spout A and Spout B..................................................................25
Optional Extensions.................................................................................28
Continuing Equipment Setup.....................................................................28
Touchscreen Operations.................................................................................30
Enabling the Dual Spout System.................................................................30
Continuing Touchscreen Operations............................................................32
Ordering/Service Information............................................................................34
©2014 Flavor Burst Company
All Rights Reserved

TABLE OF CONTENTS

Printed in February
Printed in
The United States of America

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS BASE SS-2S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Flavor Burst TS BASE SS-2S

  • Page 1: Table Of Contents

    ® Flavor Burst Soft Serve System - Operations Manual Supplement MODELS: TS BASE SS-2S TS BASE BEV-2S TS BASE FCB-2S Manufactured by Flavor Burst Company 499 Commerce Drive Danville, IN 46122 For general information and to locate a distributor near you, call or visit our website: Phone: (317) 745-2952 www.flavorburst.com...
  • Page 2: Parts Identification/Function

    Transports syrup from the bag to the pumps. STAINLESS TUBE / CABLE CASING Attaches the flavor lines and/or cables to the MIS 3196 ASSEMBLY side of the freezer. FLAVOR BURST SOFT SERVE Houses syrup trays and bags. CABINET ASSEMBLY CAB 113 FLAVOR TRAY Houses syrup bags.
  • Page 3 General System Overview (Continued) Figure 1...
  • Page 4 Cabinet – (See Figure 2) ITEM PART NO. DESCRIPTION QTY. FUNCTION ELECTRONICS SYSTEM Houses microprocessor and electronics. Holds tray support brackets and panel CAB 135R-A RIGHT SIDE PANEL brackets. CAB 145 TRAY SUPPORT BRACKET Supports flavoring trays. Fastens panel brackets to divider panel, FAS 2024 8-32 X 1/4 PAN HEAD secures sides.
  • Page 5 Cabinet (Continued) ITEM PART NO. DESCRIPTION QTY. FUNCTION FOR SOFT SERVE SYSTEMS: Pumps 20-1 SYR 307 PERISTALTIC SYRUP PUMP syrup from flavor bags into flavor lines. OR… FOR BEVERAGE & FCB SYSTEMS: 20-2 SYR 926 PERISTALTIC SYRUP PUMP Pumps syrup from flavor bags to flavor lines. Support for syrup trays and spacing CAB 155L PUMP MOUNTING STRIP...
  • Page 6 PAGE INTENTIONALLY LEFT BLANK...
  • Page 7 Cabinet Figure 2...
  • Page 8 Injector Assembly and Related Parts (See Figure 3A) ITEM PART NO. DESCRIPTION QTY. FUNCTION INJECTOR ASSEMBLY WITH SYRUP INJ 424TS Transports and blends syrup into product. LINES, ADAPTER, & BRACKET Connects flavor line to inject syrups into INJ 422 INJECTOR HEAD ASSEMBLY product.
  • Page 9 Injector Assembly and Related Parts (Continued) ITEM PART NO. DESCRIPTION QTY. FUNCTION INJ 323TS INJECTOR ASSEMBLY - NO HEAD Powers Injector system. INJ 330TS INJECTOR MOTOR ASSEMBLY 1 ea. Supplies power to Motor which turns gears. Gears turn Gear Cartridge for even syrup INJ 331 INJECTOR GEARBOX ASSEMBLY 1 ea.
  • Page 10 Blending Assembly and Related Parts (See Figure 3B) ITEM PART NO. DESCRIPTION QTY. FUNCTION VERTICAL BLENDING ASSEMBLY INJ 424VTS WITH SYRUP LINES, ADAPTER, & Transports and blends syrup into product. BRACKET Connects flavor line to inject syrups into INJ 422 BLENDING HEAD ASSEMBLY 1 ea.
  • Page 11 Blending Assembly and Related Parts (Continued) ITEM PART NO. DESCRIPTION QTY. FUNCTION INJ 323TS BLENDING ASSEMBLY - NO HEAD Powers Blending system. INJ 330TS BLENDING MOTOR ASSEMBLY 1 ea. Supplies power to Motor which turns gears. Gears turn Gear Cartridge for even syrup INJ 331 BLENDING GEARBOX ASSEMBLY 1 ea.
  • Page 12 FCB Door Spout Assembly and Related Parts (See Figure 3C) ITEM PART NO. DESCRIPTION QTY. FUNCTION ADPT TY80S- MODIFIED FCB FREEZER SPOUT FOR FCB SYSTEMS: Dispenses product ASSEMBLY blended with syrups. MODIFIED DOOR SPOUT FCB 112 Dispenses product mixed with flavorings. ASSEMBLY RUB 652-RSS SMALLER SYRUP PORT O-RING...
  • Page 13 FCB Door Spout Assembly and Related Parts Figure 3C...
  • Page 14 Syrup Pump and Related Parts (See Figure 4) ITEM PART NO. DESCRIPTION QTY. FUNCTION SOFT SERVE SYRUP PUMP Pumps syrup from flavor bags to flavor SOFT SERVE SYRUP PUMP FOR SOFT SERVE SYSTEMS: Pumps lines. SYSTEM syrup from flavor bags to flavor lines. SOFT SERVE SYRUP PUMP Pumps syrup from bags to flavor lines.
  • Page 15 ITEM PART NO. DESCRIPTION QTY. FUNCTION SYR 901 6' 9-TUBE ASSEMBLY TUBE Brings syrup from pump to Injector Head. Connects flavor lines to the internal ROT 511 LINE COUPLER NUT 9-Tube Assembly. Connects internal 9-Tube Assembly to ROT 512 TUBE CONNECTOR BODY flavor lines.
  • Page 16 Sanitizer Pump and Related Parts (See Figure 5) ITEM PART NO. DESCRIPTION QTY. FUNCTION FOR SOFT SERVE SYSTEMS: Flushes SANITIZER FLUSH TUBE MIS 3028-80 ASSEMBLY – SOFT SERVE flavor lines with sanitizer when attached. FIX 1054 FLAVOR LINE FLUSH FITMENT 1 ea.
  • Page 17 Sanitizer Pump and Related Parts Figure 5...
  • Page 18 FAS 2014 8-32 X 1/2" PAN HEAD unit. MIS 3150 FLAVOR BURST LOGO DECALS Displays Flavor Burst trademark logo. STAINLESS 9-TUBE CASING Protects and holds the cables and 9-Tube MIS 3196 ASSEMBLY Assembly in place on the freezer side panel.
  • Page 19 Electronic Parts and Connections Figure 6...
  • Page 20 Soft Serve Spare Parts Kit (See Figure 7A) ITEM PART NO. DESCRIPTION QTY. FUNCTION Houses extra spare parts and wear SPR 5800A SPARE PARTS KIT – SOFT SERVE items. Turns the gear box gears, powered by the CW 137 DRIVE MOTOR GEAR drive motor.
  • Page 21 Beverage Spare Parts Kit (See Figure 7B) ITEM PART NO. DESCRIPTION QTY. FUNCTION SPARE PARTS KIT – SPR 5800BEV Houses extra spare parts and wear items. TOUCHSCREEN BEVERAGE ELE 444 1 AMP, 1 1/4" SLOW BLOW FUSE System overload protection. Provided to attach switch to freezer or mount MIS 3076 ADHESIVE PAD...
  • Page 22 FCB Spare Parts Kit (See Figure 7C) ITEM PART NO. DESCRIPTION QTY. FUNCTION SPR 5800FCB SPARE PARTS KIT FOR FCB Houses extra spare parts and wear items. ELE 444 1 AMP, 1 1/4" SLOW BLOW FUSE System overload protection. Activates the ELE 530 Spigot Switch. Not MIS 3179 MAGNETIC ACTUATOR PIN used with the FB 80FCB Auto Draw Valve...
  • Page 23: Equipment Setup

    REPLACE IF NECESSARY. The BASE-2S system is designed to work with 2. Follow the sanitizer line from the tank to the an existing Flavor Burst Touchscreen system. point closest to the Base-2S unit. Cut the Each system is installed on separate spouts, sanitizer line at this point.
  • Page 24: Installing The Sanitizer Line - Internal Tank

    Installing the Sanitizer Line – Internal Tank 4. Insert the Base-2S sanitizer line into the remaining T-Connector opening. Follow these instructions when connecting the sanitizer line to an internal sanitizer tank. These tanks are located inside a cabinet, such as a Deluxe or Integrated cabinet. 1.
  • Page 25 8. Drill a ½” hole on the mark. 4. Attach the Base-2S sanitizer line to the remaining T-Connector opening. 9. Insert the bushing provided into this hole. 5. If you are working on an Integrated unit, pass the Base-2S sanitizer line through the cart’s back panel, through the same opening the 9-Tube Assembly passes.
  • Page 26: Accessing The Touchscreen Board

    Accessing the Touchscreen Board Assigning Spout A and Spout B The Base-2S unit does not come with its own The Touchscreen Controller Cable can only be Touchscreen. It is designed to connect to your used on the Base-2S cabinet, and it must be existing Touchscreen unit.
  • Page 27 3. Insert the small connection of the Rotor 7. Clamp the strain relief around the spigot Cable through one of the open holes near switch cable and insert it into the housing the switch on the housing. Connect Rotor opening. Cable to the small port of the Controller Cable.
  • Page 28: Set Up Spout A With Base-2S Cabinet And Spout B With Standard Cabinet

    Set Up Spout A with Base-2S Cabinet and 4. Connect Rotor Cable to the small port of the Spout B with Standard Cabinet Controller Cable. If attaching the Base-2S cabinet to Spout A and the standard cabinet to Spout B, proceed. If the Base-2S cabinet attaches to Spout B, follow the instructions in the previous section.
  • Page 29: Optional Extensions

    8. Clamp the strain relief around the spigot Optional Extensions switch cable and insert it into the housing opening. Your Base-2S unit and second freezer should be stationed as close to the first freezer and your standard unit as possible. Should you require additional length to your cables and tubing, please contact your local distributor.
  • Page 31: Touchscreen Operations

    Your Touchscreen will have to be reconfigured in order to control both systems. Follow these instructions to set up your Touchscreen. 1. Ensure the Flavor Burst system and the 6. Read the instructions on the Pre-Setup freezer are connected to a power source Verification screens (press Next to see and turned on.
  • Page 32 10. Press the “Setup Second Unit” key. 7. Press the NEXT key. 11. If the Base-2S cabinet is set up with 8. If the standard cabinet is set up with Spout A (the freezer or spout on the left), Spout A (the freezer or spout on the left), check both boxes under the Spout A check both boxes under the Spout A column.
  • Page 33: Continuing Touchscreen Operations

    13. Press DONE to return to the main screen. 2. If you are used to a single spout system, you will notice some changes to your Touchscreen displays, such as the initial “Select Spout A or B” screen and the Setup screen showing “Spout A Maintenance”...
  • Page 34 PAGE INTENTIONALLY LEFT BLANK...
  • Page 35: Ordering/Service Information

    2. Serial Number ____________________________________ 3. Voltage _________________________________________ 4. Maximum Fuse Size __________________________ Amps 5. Minimum Wire Ampacity _______________________ Amps Flavor Burst is a registered trademark of the Flavor Burst Company. Taylor is a registered trademark of the Taylor Company. All rights reserved.

This manual is also suitable for:

Ts base bev-2sTs base fcb-2s

Table of Contents