Conduit terminal
Wire the conduit terminal as illustrated below:
・ Tighten parts to the torque values specified below.
・ Seal the piping (G1/2) properly with the specified conduit.
Round head combination screw
M3 Tightening torque: 0.5 to 0.6 N·m
- mark
mark
Round head combination screw
M3 Tightening torque: 0.5 to 0.6N·m
Cross section A-A
(Wiring inside)
■ Conduit
Use the tightening torque below for the conduit.
Class B coil: AWG20 Insulator O.D. 2.5 mm
Lead wire
Conduit piping
(Port size G1/2 Tightening torque 0.5 to 0.6N·m)
Rated voltage
DC
100VAC
200VAC
Other AC
* There is no polarity.
Part name
Seal
Note) Order separately.
Terminal cover
+ mark
Conduit terminal
Seal
Lead wire color
(1)
(2)
Black
Red
Blue
Blue
Red
Red
Grey
Grey
Part No.
VCW20-15-6
- 8 -
Tightening torque: 0.5 to 0.6N·m
XSA-OMS0001-B