DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual
Access ID (1-128)
Enter the Access ID that will be used to configure the Flow Metering parameters, enter a value
between 1 and 128.
Mode
Select the mode to be used either trTCM or srTCM and enter the corresponding information.
trTCM – Two Rate Three Color Marker, marks packets green, yellow or red based on two rates
and two burst sizes. It is useful when peak rates need to be enforced.
srTCM – Single Rate Three Color Marker, marks packets green, yellow or red based on a rate
and two burst sizes. This is useful when only burst size matters.
Action
Conform – Specifies the action when the packet is in "green color" mode.
Exceed – Specifies the action when the packet is in "yellow color" mode.
Violate – Specifies the action when the packet is in "red color" mode.
Click Apply to implement changes made, click Back to return to the ACL Flow Meter.
CIR(64Kbps) value 0-15624 – Specifies the Committed Information Rate of the packet.
The unit is 64Kbps. That is to say, 1 means 64Kbps.
PIR(64Kbps) value 0-15624 – Specifies the Peak Information Rate of the packet. The
unit is 64Kbps. That is to say, 1 means 64Kbps.
CBS(Kbyte) value 0-16384 – Specifies the Committed Burst Size of the packet. The
unit is Kbyte. That is to say, 1 means 1Kbyte. This parameter is optional and the default
value is 4*1024. The max value is 16*1024.
PBS(Kbyte) value 0-16384 – Specifies the Peak Burst Size of the packet. The unit is
Kbyte. That is to say, 1 means 1Kbyte. This parameter is optional and the default value
is 4*1024. The max value is 16*1024.
CIR(64Kbps) value 0-15624 – Specifies the Committed Information Rate of the packet.
The unit is 64Kbps. That is to say, 1 means 64Kbps.
CBS(Kbyte) value 0-16384 – Specifies the Committed Burst Size of the packet. The
unit is Kbyte. That is to say, 1 means 1Kbyte. The maximum value is 16*1024.
EBS(Kbyte) value 0-16384 – Specifies the Excess Burst Size of the packet. The unit is
Kbyte. That is to say, 1 means 1Kbyte. The maximum value is 16*1024.
Replace DSCP – Allows you to change the dscp of the packet
Counter – Allows you to set the counter of the packet.
Permit – Permits the packet.
Replace DSCP – Allows you to change the DSCP of the packet.
Counter – Allows you to set the counter of the packet.
Drop – Drops the packet.
Permit – Permits the packet.
Replace DSCP – Allows yout to change the DSCP of the packet.
Counter – Allows you to set the counter of the packet.
Drop – Drops the packet.
219