Fibra data transfer protocol
The keypad uses Fibra technology to transmit alarms and events and to update
the rmware. It is a wired data transfer protocol for fast and reliable two-way
communication between the hub and connected devices.
Learn more
Sending events to the monitoring station
The Ajax system can transmit alarms to both
the central monitoring station (CMS) in the formats of SurGard (Contact ID), SIA
(DC-09), ADEMCO 685, and
KeyPad TouchScreen can transmit the following events:
1. Entry of the duress code.
2. Pressing the panic button. Each button has its own event code.
3. Keypad locking due to an unauthorized access attempt.
4. Tamper alarm and recovery.
5. Connection loss/restoration between KeyPad TouchScreen and the hub.
6. Arming/disarming the system.
7. Unsuccessful attempt to arm the security system (with the
check
enabled).
8. Permanent deactivation/activation of the keypad.
9. One-time deactivation/activation of the keypad.
10. Low voltage detection on the Fibra line and voltage restoration to normal
values.
11. Low backup battery charge and battery charge restoration.
12. Backup battery malfunction/restoration.
13. Malfunction detection; the keypad cannot charge the backup battery.