Commissioning
The desired units can be selected in the System units submenu. The wizards systematically
guide the user through all the parameters required for configuration, such as parameters for
measurement or outputs.
The wizards available in the particular device can vary on account of the device version
(e.g. sensor).
Wizard
System units
Medium selection
Display
Low flow cut off
Advanced setup
8.5

Protecting settings from unauthorized access

The following write protection options exist in order to protect the configuration of the
measuring device from unintentional modification:
• Protect access to parameters via access code
• Protect access to local operation via key locking
• Protect access to measuring device via write protection switch
For detailed information on protecting the settings against unauthorized access, see the
Operating Instructions for the device.
8.6

Application-specific commissioning

8.6.1
Steam application
Select medium
Navigation:
Setup → Medium selection
1.
Open the Medium selection wizard.
2.
In the Select medium parameter, select the Steam option.
40
Meaning
Configure the units for all measured variables
Definition of the medium
Configuration of the measured value display
Configuration of the low flow cut off
Additional parameters for configuration:
• Medium properties
• External compensation
• Sensor adjustment
• Totalizer 1 to n
• Heartbeat
• Configuration backup display
• Administration
Flowmeter Proline 200 PROFINET with Ethernet-APL