REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd�
Sub cmd�
Data
1A*
05
SCOPE > SCOPE SET
01 86
00 ~ 02
01 87
00/01
01 88
00/01
01 89
00 ~ 03
01 90
00/01
01 91
See p� 21�
01 92
See p� 21�
01 93
See p� 21�
01 94
00/01
01 95
00 ~ 02
01 96
00 ~ 02
01 97
00 ~ 07
01 98
00/01
01 99
See p� 21�
02 00
See p� 21�
02 01
See p� 21�
02 02
See p� 21�
02 03
See p� 21�
02 04
See p� 21�
02 05
See p� 21�
02 06
See p� 21�
02 07
See p� 21�
02 08
See p� 21�
02 09
See p� 21�
02 10
See p� 21�
Description
Send/read the CENTER Type
Display setting
( 00=Filter Center,
01=Carrier Point Center,
02=Carrier Point Center (Abs� Freq�))
Send/read the Marker Position
(FIX Type/SCROLL Type) setting
(00=Filter Center, 01=Carrier Point)
Send/read the VBW setting
(00=Narrow, 01=Wide)
Send/read the Averaging setting
(00=OFF, 01=2, 02=3, 03=4)
Send/read the Waveform Type setting
(00=Fill, 01=Fill+Line)
Send/read the Waveform Color
(Current) setting
Send/read the Waveform Color
(Line) setting
Send/read the Waveform Color
(Max Hold) setting
Send/read the Waterfall Display setting
(00=OFF, 01=ON)
Send/read the Waterfall Speed setting
(00=Slow, 01=Mid, 02=Fast)
Send/read the Waterfall Size
(Expand Screen) setting
(00=Small, 01=Mid, 02=Large)
Send/read the Waterfall Peak Color
Level setting
(00=Grid1 ~ 07=Grid8)
Send/read the Waterfall Marker
Auto-hide setting
(00=OFF, 01=ON)
Fixed Edges > 144M >
Send/read the No�1 setting
Fixed Edges > 144M >
Send/read the No�2 setting
Fixed Edges > 144M >
Send/read the No�3 setting
Fixed Edges > 144M >
Send/read the No�4 setting
Fixed Edges > 430M >
Send/read the No�1 setting
Fixed Edges > 430M >
Send/read the No�2 setting
Fixed Edges > 430M >
Send/read the No�3 setting
Fixed Edges > 430M >
Send/read the No�4 setting
Fixed Edges > 1200M >
Send/read the No�1 setting
Fixed Edges > 1200M >
Send/read the No�2 setting
Fixed Edges > 1200M >
Send/read the No�3 setting
Fixed Edges > 1200M >
Send/read the No�4 setting
Cmd�
Sub cmd�
1A*
05
SCOPE > SCOPE SET
02 11
See p� 21�
02 12
See p� 21�
02 13
See p� 21�
02 14
See p� 21�
02 15
See p� 21�
02 16
See p� 21�
02 17
See p� 21�
02 18
See p� 21�
02 19
See p� 21�
02 20
See p� 21�
02 21
See p� 21�
02 22
See p� 21�
AUDIO > AUDIO SCOPE SET
02 23
00/01
02 24
See p� 21�
02 25
00/01
02 26
See p� 21�
VOICE
02 27
00 00 ~ 02 55 Send/read the TX LEVEL setting
02 28
00/01
02 29
01 ~ 15
KEYER > KEYER 001
02 30
00 ~ 04
02 31
01 ~ 08
02 32
00 01 ~ 99 99 Send/read Present Number setting
KEYER > CW-KEY SET
02 33
00 00 ~ 02 55 Send/read Side Tone Level setting
10
Data
Description
Fixed Edges > 2400M >
Send/read the No�1 setting
Fixed Edges > 2400M >
Send/read the No�2 setting
Fixed Edges > 2400M >
Send/read the No�3 setting
Fixed Edges > 2400M >
Send/read the No�4 setting
Fixed Edges > 5600M >
Send/read the No�1 setting
Fixed Edges > 5600M >
Send/read the No�2 setting
Fixed Edges > 5600M >
Send/read the No�3 setting
Fixed Edges > 5600M >
Send/read the No�4 setting
Fixed Edges > 10G >
Send/read the No�1 setting
Fixed Edges > 10G >
Send/read the No�2 setting
Fixed Edges > 10G >
Send/read the No�3 setting
Fixed Edges > 10G >
Send/read the No�4 setting
Send/read the FFT Scope
Waveform Type setting
(00=Line, 01=Fill)
Send/read the FFT Scope
Waveform Color setting
Send/read the FFT Scope
Waterfall Display setting
(00=OFF, 01=ON)
Send/read the Oscilloscope
Waveform Color setting
(00 00=0% ~ 02 55=100%)
VOICE TX SET >
Send/read the Auto Monitor setting
(00=OFF, 01=ON)
VOICE TX SET >
Send/read the Repeat Time setting
(01=1sec ~ 15=15sec)
Send/read the Number Style setting
( 00=Normal, 01=190→ANO,
02=190→ANT, 03=90→NO,
04=90→NT)
Send/read the Count Up Trigger setting
(01=M1 ~ 08=M8)
(00 01=1 ~ 99 99=9999)
(00 00=0% ~ 02 55=100%)
Need help?
Do you have a question about the IC-905 and is the answer not in the manual?
Questions and answers