Download Print this page
Altronix TROVE T1MK1F4 Installation Manual
Altronix TROVE T1MK1F4 Installation Manual

Altronix TROVE T1MK1F4 Installation Manual

Altronix/mercury kits

Advertisement

Quick Links

Access & Power Integration
Altronix/Mercury Kits
Models Include:
T1MK1F4
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) VR6 - Voltage Regulator
- One (1) ACM4 - Fused Access Power Controller
T1MK1F4Q
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) LINQ2 - Network Communication Module
- One (1) VR6 - Voltage Regulator
- One (1) ACM4 - Fused Access Power Controller
T1MK1F4S
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) VR6 - Voltage Regulator
- One (1) ACM4 - Fused Access Power Controller
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T1MK1F4SQ
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) LINQ2 - Network Communication Module
- One (1) VR6 - Voltage Regulator
- One (1) ACM4 - Fused Access Power Controller
- One (1) PDS8 - Dual Input Fused Power Distribution Module
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners.
Rev. T1MK_081523
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
T1MK1F4D
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) VR6 - Voltage Regulator
- One (1) ACM4CB - PTC Access Power Controller
T1MK1F4DQ
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) LINQ2 - Network Communication Module
- One (1) VR6 - Voltage Regulator
- One (1) ACM4CB - PTC Access Power Controller
T1MK1F4SD
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) VR6 - Voltage Regulator
- One (1) ACM4CB - PTC Access Power Controller
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
T1MK1F4SDQ
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) eFlow4NB - Power Supply/Charger
- One (1) LINQ2 - Network Communication Module
- One (1) VR6 - Voltage Regulator
- One (1) ACM4CB - PTC Access Power Controller
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
More than just power.™

Advertisement

loading
Need help?

Need help?

Do you have a question about the TROVE T1MK1F4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix TROVE T1MK1F4

  • Page 1 4 Door Kit with PTC Outputs Fully assembled kit includes: Fully assembled kit includes: - Trove1 enclosure with TM1 Altronix/Mercury backplane - Trove1 enclosure with TM1 Altronix/Mercury backplane - One (1) eFlow4NB - Power Supply/Charger - One (1) eFlow4NB - Power Supply/Charger...
  • Page 2: Configuration Chart

    Overview: Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to four (4) doors in a single enclosure. Configuration Chart:...
  • Page 3 Pem Mounting EP1502, LP1502, MR52, MR16IN, MR16OUT EP1501, LP1501, MR51e, MR62e MR50 EP2500, LP2500, MUX8 Fig. 2 Fig. 2a ON-5V OFF-12V Snap On Spacer Altronix VR6 Flying Leads Backplane Mercury Board TRIGGER INPUT Altronix eFlow4NB IN GND IN GND IN GND...
  • Page 4 Access Controller Position Chart for the Following Models: Mercury Access Controller Pem Mounting EP1502, LP1502, MR52, MR16IN, MR16OUT EP1501, LP1501, MR51e, MR62e MR50 EP2500, LP2500, MUX8 Fig. 3 Fig. 3a Altronix LINQ2 Module ON-5V OFF-12V Snap On Spacer Altronix VR6 Flying Backplane Leads...
  • Page 5 EP2500, LP2500, MUX8 Fig. 4 Fig. 4a Snap On Spacer Altronix PDS8(CB) Backplane Mercury Board Altronix eFlow4NB Altronix VR6 is mounted under PDS8(CB) TRIGGER INPUT IN GND IN GND IN GND IN GND Altronix ACM4(CB) OFF - 24V ON - 12V...
  • Page 6 Fig. 5 Fig. 5a Altronix LINQ2 Module Snap On Spacer Altronix PDS8(CB) Backplane Mercury Board Altronix eFlow4NB Altronix VR6 is mounted under PDS8(CB) TRIGGER INPUT IN GND IN GND IN GND IN GND Altronix ACM4(CB) OFF - 24V ON - 12V...
  • Page 7 Notes: - 7 - Trove1 Mercury Kits Installation Guide...
  • Page 8 1.115” (28.3mm) 1.36” (34.5mm) 1.25” (31.8mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty...

This manual is also suitable for:

Trove t1mk1f4dTrove t1mk1f4qTrove t1mk1f4dqTrove t1mk1f4sTrove t1mk1f4sdTrove t1mk1f4sq ... Show all