• Keep the screwdriver vertical to the Inverter.
NOTE
• Refer to Page 29 for tightening torques.
5.5 mm
(0.22 in.)
Open the front cover and verify that the strip length is 5.5 mm
(0.22 in.).
Scale

Wiring Inspection

After completing wiring, check the following.
• Wiring is proper.
• Wire clippings or screws are not left in the Inverter.
• Screws are securely tightened.
• Bare wires in the terminals do not contact other terminals.
WARNING
1. If the FWD (or REV) Run Command is given when the
NOTE
2. To set the 3-wire sequence, set terminal S3 (n052) to 0.
The wire sheath strip length
must be 5.5 mm (0.22 in.).
5.5mm
If the power supply is turned ON while the FWD (or
REV) Run Command is given, the motor will start
automatically.
Turn the power supply ON after verifying that the
RUN signal is OFF.
Failure to observe this warning may result in injury.
Run Command from the control circuit terminal is
selected (n003 = 1), the motor will start automatically
after the main circuit input power supply is turned ON.
CONTACT OUTPUT
SW1
SW2
4 Wiring