Omron V7-IP65 User Manual page 227

Compact sensorless vector inverter
Hide thumbs Also See for V7-IP65:
Table of Contents

Advertisement

No. Register
No. for
Trans-
mission
032
0120
Jog Frequency
033
0121
Frequency Reference Upper
Limit
034
0122
Frequency Reference Lower
Limit
035
0123
Setting/Displaying Unit Selec-
tion for Frequency Reference
036
0124
Motor Rated Current
037
0125
Electronic Thermal Motor
Protection Selection
038
0126
Electronic Thermal Motor Pro-
tection Time Constant Setting
039
0127
Selecting Cooling Fan
Operation
040
0128
Motor Rotation Direction
041
0129
Acceleration Time 3
042
012A
Deceleration Time 3
043
012B
Acceleration Time 4
044
012C
Deceleration Time 4
045
012D
Frequency Reference Bias
Step Amount (Up/Down
Command 2)
046
012E
Frequency Reference Bias
Accel/Decel Rate (Up/Down
Command 2)
047
012F
Frequency Reference Bias
Operation Mode Selection
(Up/Down Command 2)
048
0130
Frequency Reference Bias
Value (Up/Down Command
2)
049
0131
Analog Frequency Refer-
ence Fluctuation Limit Level
(Up/Down Command 2)
226
Name
Setting Range Setting Unit
0.00 to 400.0
0% to 110%
0% to 110%
0 to 3999
0% to 150% of
Inverter rated
1 to 60 min
0.00 to 6000 s Depends on
0.00 to 6000 s Depends on
0.00 to 6000 s Depends on
0.00 to 6000 s Depends on
0.00 Hz to
-99.9% to
n011=100%
n011=100%
0.01 Hz (less
Hz
than 100
Hz)/
0.1 Hz (100
Hz or more)
1%
1%
-
0.1 A
current
0 to 4
-
1 min
0, 1
-
0, 1
-
n018 setting
n018 setting
n018 setting
n018 setting
0.01 Hz
99.99 Hz
0, 1
-
0, 1
-
0.1%
100.0%
0.1% to
0.1%
100.0%
Factory
Change
User
Setting
during
Set-
Opera-
ting
tion
6.00 Hz
Yes
100%
No
0%
No
0
No
(Note 3)
No
0
No
8 min
No
0
No
0
No
10.0 s
Yes
10.0 s
Yes
10.0 s
Yes
10.0 s
Yes
0.00 Hz
Yes
0
Yes
0
Yes
0.0%
No
1.0%
Yes
Ref.
Page
70
72
72
176
130
130,
98
130
135
39
73
73
73
73
110
110
110
110
110