By setting a multi-function input selection (any one of n050 to n056) to
11 (acceleration/deceleration time selection 1) or 27 (acceleration/decel-
eration time selection 2), the acceleration/deceleration time is selected
by ON/OFF combinations of acceleration/deceleration time selection 1
and acceleration/deceleration time selection 2 (terminals S1 to S7).
The combinations of acceleration/deceleration time selection settings
are shown below.
Accleration/
Deceleration
Time Selection 1
OFF
ON
OFF
ON
No.
n019
Acceleration Time 1
n020
Deceleration Time 1
n021
Acceleration Time 2
n022
Deceleration Time 2
n041
Acceleration Time 3
n042
Deceleration Time 3
n043
Acceleration Time 4
n044
Deceleration Time 4
Accleration/
Deceleration
Time Selection 2
OFF
OFF
ON
ON
Name
(See the next
6 Programming Features
Acceleration Time Deceleration Time
Acceleration time 1
(n019)
Acceleration time 2
(n021)
Acceleration time 3
(n041)
Acceleration time 4
(n043)
Unit
Setting Range Factory
Depends on
n018 setting.
table.)
Deceleration time 1
(n020)
Deceleration time 2
(n022)
Deceleration time 3
(n042)
Deceleration time 4
(n044)
Depends on
n018 setting.
(See the next
table.)
Setting
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
73