Omron V7-IP65 User Manual page 145

Compact sensorless vector inverter
Hide thumbs Also See for V7-IP65:
Table of Contents

Advertisement

• Simultaneous Broadcasting Data (available only for write in)
Register
No.
0001H
0002H
Bit signals not defined as the broadcast operation signals are used as
the local station data signals.
• Monitor Data (available only for read out)
Register
No.
0020H
144
Bit
0
Run Command
1
Reverse Run Command 1: Reverse run 0: Forward run
2
(Not used)
3
(Not used)
4
External fault
5
Fault Reset Command
6-F
(Not used)
Frequency reference 30000/100 % fixed unit
(Data is converted into 0.01 Hz inside the Inverter, and fractions
are rounded off.)
Bit
0
Run Command
1
Reverse Run Command 1: Reverse run 0: Forward run
2
Inverter operation ready 1: Ready
3
Fault
4
Data setting error
5
Multi-function output 1
6
Multi-function output 2
7
Multi-function output 3
8-F
(Not used)
Description
1: Run
1: Fault (EFO)
1: Fault Reset
Description
1: Run
1: Fault
1: Error
(1: MA ON
(1: P1 ON
(1: P2 ON
0: Stop
0: Stop
0: Not ready
0: MA OFF)
0: P1 OFF)
0: P2 OFF)