System Configuration Examples - Omron V640 User Manual

V640 series amplifier unit, cidrw head, cidrw controller, cidrw controller
Hide thumbs Also See for V640:
Table of Contents

Advertisement

SECTION 6
Appendix

System Configuration Examples

When SECS is Used
Communication with the host device is possible using the SECS protocol.
Host
This is e.g. a host,
or equipment con-
troller.
With the above system configuration, the Amplifier Unit connected directly to the CIDRW Controller
converts signals from RS-232C to RS-485. If this Amplifier Unit is removed, communications will not be
possible with the other Amplifier Units. If the Amplifier Unit connected directly to the CIDRW Controller
must be removed while the system is operating, insert a Link Unit (V700-L11) between the CIDRW
Controller and the first Amplifier Unit. If an Amplifier Unit on the end of the network is removed, be sure
to turn ON the terminating resistance on the Amplifier Unit that will end up on the end of the network
while the Amplifier Unit is removed.
CIDRW System
104
User's Manual
CIDRW Controller
V700-L22
RS-232C
SECS I/II
Multiple Amplifier Units
are controlled in
response to commands
(SECS) from the host
device.
Max. 50 m
RS-232C
RS-232C
SECS I/II
Amplifier Unit
V640-HAM12
RS-232C
RS-485
These are units that
control a CIDRW Head.
Up to 31 units can be
connected.
Link unit
V700-L11
Just the relevant Amplifier Unit can be
removed and replaced while the power
remains on.
RS-485
Max. 50 m
CIDRW Head
V640-HS62
These are antennae for
reading the carrier IDs
from the ID Tags and
writing the carrier IDs.
Up to 31 units can be connected.